Download Print this page
Grizzly H3258 Manual
Grizzly H3258 Manual

Grizzly H3258 Manual

Air filter/ regulator/ lube with gauge

Advertisement

Quick Links

When installed in an air system, the Model H3258
removes micro-particles and moisture droplets, lubri-
cates your air tools, and regulates air flow.
INSTALLING REGULATOR
To install the Model H3258 to your pneumatic
device:
Disconnect the compressor system from the
1.
power source!
Drain the air pressure out of the tank and lines
2.
before connecting the Model H3258 to your air
line.
3.
Mount the Model H3258 (in the upright position
shown in Figure 1) on a wall close to the area of
air tool operation, using the wall mount guide
holes. You can also connect it directly onto the
compressor shut off valve. Note—Place the
Model H3258 away from direct sun or hazardous
materials.
Control
Knob
Pressure
Gauge
Drain
Valve
Figure 1. Identification and mounting orientation.
1
4.
Connect a
" NPT air line (A), in Figure 2, to the
4
shut-off valve on your air compressor. Seal all
the fittings with teflon tape to prevent leaks and
product failure.
Air Filter/ Regulator/ Lube
5.
6.
From Compressor
7.
Oil Fill Cap
Screw
8.
Wall
9.
Mounts
10. Check for air leaks along the line by using
If you need additional help with this procedure,
call our service department at: (570) 546-9663.
Model H3258
with Gauge
Connect the air line (A) to the line-IN
threads (B) on the Model H3258 as shown in
Figure 2. Note—Use as short of an air line
as possible, with minimal bends, to maintain
an accurate working pressure.
Thread on a male connector (D) to the Line
"OUT" threads (C) followed by a quick cou-
pler (E) as shown in Figure 2.
INSTALL THIS SYSTEM AS CLOSE TO THE AIR
TOOL AS POSSIBLE FOR BEST PERFORMANCE!
Air Hose
C
A
B
Figure 2. Connection diagram.
The quick coupler will accept a hose
connector (F) that attaches to the air hose
(G) going to your tool.
Fill the oil cup to the designated fill level with
air tool oil.
When the set up is complete and the fittings
are secure, start your air compressor and let
the air pressure build to the operating level.
soapy water. If there are leaks present, dis-
connect the line on both sides of the leak.
Reseal the leaking fittings with teflon tape
and reconnect the line.
1
" NPT
4
To Air Tool
Air Hose
D
E
F
G

Advertisement

loading

Summary of Contents for Grizzly H3258

  • Page 1 Model H3258 Air Filter/ Regulator/ Lube with Gauge When installed in an air system, the Model H3258 Connect the air line (A) to the line-IN ⁄ " NPT removes micro-particles and moisture droplets, lubri- threads (B) on the Model H3258 as shown in cates your air tools, and regulates air flow.
  • Page 2 Before filling the oil reserve, release all air ADJUSTING REGULATOR pressure in the tank and lines, then remove the cap screw above the oil reservoir shown in Figure 4. To adjust the regulator air pressure on the Model H3258: Fill the oil cup between the minimum and max- imum level marks on the side of the bowl.