Rackmount power strips and isobar rackmount surge suppressors/ line-noise filters (16 pages)
Summary of Contents for Tripp Lite TouchMaster (MT-6
Page 1
Standards Certified by UL Your Tripp Lite Under-Monitor Surge Suppressor protects your sensitive electronic equip- ment from spikes, surges and line noise on the AC power line. It features convenient, fin- gertip control of AC power for your computer and various peripherals, as well as advanced diagnostic indicators that display power-protection status.
Page 2
Introduction CONNECTING YOUR UNDER-MONITOR SURGE SUPPRESSOR Connection to AC Power Line (all models) The Under-Monitor Surge Suppressor power cord should only be connected to a standard 3-wire grounded 120-Volt AC, 60-Hz outlet. CAUTION! DO NOT connect to an ungrounded AC outlet. DO NOT connect to 2-wire extension cords or adapters.
Introduction continued CAUTION! DO NOT drill into any part of the housing. DO NOT open, as there are no user-serviceable parts inside. Connecting Your Equipment (See Front and Rear Panel illustrations on page 5 for connection to your specific model.) After you have properly connected your Under-Monitor Surge Suppressor to the AC line and telephone line (if applicable), you can connect the AC power cords of your equip- ment to the surge suppressor.
Features Circuit Breaker (all models) If the current draw of the equipment connected to the surge suppressor exceeds 15 amps for longer than a few seconds, the circuit breaker will open (trip) to prevent any possible damage. When the circuit breaker trips, the plunger will be extended. Remove the overload and allow the breaker to cool for one minute before depressing the plunger to reset.
Front Panels FRONT PANEL FEATURES Switches 1) Individual 2) Master Indicator Lights 3) Protection Present 4) Line Fault TouchMaster 5) Line “OK” 6) Low Voltage TouchMaster PLUS Command Console Command Console PLUS Command Console Compact Command Console Compact...
"Specifications" section. Should you require service, call Tripp Lite Customer Support at (773) 869-1234. Explain fully the perceived problem to the cus- tomer support person.
Specifications No. of AC Line Cord* No. of Control AC Energy Surge Transient Ultimate AC Receptacles Length Switches Absorption Suppression Response Dimensions Lifetime Model (NEMA 5-15R) (ft.) Master/Aux. (joules) (amp spikes)** Time (H x W x D, in.) Insurance TOUCHMASTER 1280 96,000 0 ns.
Service under this Warranty can only be obtained by your delivering or shipping the product (with all shipping or delivery charges prepaid) to: Tripp Lite, 1111 W. 35th Street, Chicago IL 60609. Seller will pay return shipping charges.