2.12 Environmental
Characteristics
Functions & OSD Operation
Operating
Conditions
Humidity
20-80%
Non-Operating
Conditions
Humidity
20-85%
Altitude
Non-Operating
Not more than 12,000m
2.12 Safety
2.12.1
Insulation
Resistance
The resistance
of the insulation
between the power terminal and the earth ground
contact is more than 10 MR while withstanding
a voltage of 3kV(DC).
Test
Conditions
Voltage
3k V (dc)
Resistance
Value
10 M_
Test
Criteria
The power
terminal
and the earth ground
contact
is more than
10M_
while
withstanding
a voltage
of 3kV(dc).
2.12.2
Insulation
Dielectric
Strength
The evaluation
conforms to safety standard of shipment area.
Test
Conditions
Voltage
3.676k Vdc (2.6K '_ac)
Time
3 sec
Current
10 iliA (max)