Table Of Contents; Storage - Greenheck APEX-200 Installation, Operation & Maintenance Manual

Energy recovery ventilator
Table of Contents

Advertisement

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation . . . . . . . . . . . . . . . . . . . . . . . . 3
Lifting . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Unit weights . . . . . . . . . . . . . . . . . . . . . . .4
Recommended roof openings . . . . . . . .4
Roof curb mounting . . . . . . . . . . . . . . . .4
Rail mounting . . . . . . . . . . . . . . . . . . . . . 5
Weatherhoods / Dampers . . . . . . . . . . . 5
Electrical connections . . . . . . . . . . . . . .6
Service Clearances . . . . . . . . . . . . . . . . . 7
Access Locations . . . . . . . . . . . . . . . . . . 7
Dimensional Data . . . . . . . . . . . . . . . . . . .7
Access Door Descriptions . . . . . . . . . . .7
Water coils . . . . . . . . . . . . . . . . . . . . . . . 8
DX coils . . . . . . . . . . . . . . . . . . . . . . . . . 8
Drain pan trap piping . . . . . . . . . . . . . . . 9
Variable Frequency Drive . . . . . . . . . . . .9
Optional Accessories . . . . . . . . . . . .12-13
Start-Up Checks . . . . . . . . . . . . . . . . . . 14
When a unit is not going to be in service for an extended amount of time, certain procedures should be
followed to keep the fans in proper operating condition.
• Rotate fan wheel monthly and purge grease from bearings once every three months
• Cover unit with tarp to protect from dirt and moisture (Note: do not use a black tarp as this will promote
condensation)
• Energize fan motor once every three months
• Store belts flat to keep them from warping and stretching
• Store unit in location which does not have vibration
• After storage period, purge grease from fan bearings before putting fan into service
If storage of unit is in a humid, dusty or corrosive atmosphere, rotate the fan and purge the bearings once a
month. Improper storage which results in damage to the unit or components will void the warranty.

Table of Contents

Fan information . . . . . . . . . . . . . . . . . . 15
Fan belt drives . . . . . . . . . . . . . . . . . . . .16
Fan RPM . . . . . . . . . . . . . . . . . . . . . . . .16
Vibration . . . . . . . . . . . . . . . . . . . . . . . . .17
Energy recovery wheel . . . . . . . . . . . . 17
Routine Maintenance . . . . . . . . . . . . . . 18
Motors . . . . . . . . . . . . . . . . . . . . . . . . . .19
Wheel and fasteners . . . . . . . . . . . . . . .19
Bearings . . . . . . . . . . . . . . . . . . . . . . . . .19
Filters / Door Seals . . . . . . . . . . . . . . . 20
Coil Maintenance . . . . . . . . . . . . . . . . . . .21
Maintenance . . . . . . . . . . . . . . . . . . . . .21
Winterizing . . . . . . . . . . . . . . . . . . . . . .21
Removing wheel segments . . . . . . . . .22
Cleaning wheel segments . . . . . . . . . . .23
Wheel belt / Wheel bearings . . . . . . . .23
Parts List . . . . . . . . . . . . . . . . . . . . . . . . .24
Sequence of Operation . . . . . . . . . . . . .25
Airflow Troubleshooting . . . . . . . . . . . .26
General Troubleshooting . . . . . . . . .27-28

Storage

2
®

Advertisement

Table of Contents
loading

Table of Contents