Power relay 1 pole - 20a, 3.0mm contact gap

Advertisement

Quick Links

POWER RELAY
1 POLE - 20A, 3.0mm contact gap
FTR-K2G Series
n FEATURES
Contact gap min. 3.0mm
l
Full disconnection
l
1 Pole, 1 Form A
l
Maximum inrush current 120A (TV-8) (UL) (VDE)
l
High insulation
l
Reinforced insulation
Insulation distance between coil and contact:
- Clearance min. 8.0mm, creepage min. 9.5mm
- Dielectric strength: 5KV
- Surge strength: 10KV
Heat resistance, flammability
l
Class B (130°C) coil wire class,
flammability UL94V-0 (plastic)
Safety standards
l
UL, CSA, VDE approved
Flux proof type. RT II
l
RoHS compliant
l
Please see page 6 for more information
n PARTNUMBER INFORMATION
FTR-K2G
[Example]
(a)
(a)
Relay type
(b)
Contact configuration
(c)
Coil type
(d)
Coil rated voltage
(e)
Contact material / TV type
Actual marking does not carry the type name : "FTR"
E.g.: Ordering code: FTR-K2GAK012T
A
K
012
T
(b)
(c)
(d)
(e)
FTR-K2G: FTR-K2G Series
A
K
012
T
Actual marking: K2GAK012T
FTR-K1 SERIES
: 1 form A
: Standard type (1,000mW)
: 5.....110VDC
Coil rating table at page 3
: AgSnO
(TV-5)
2
1

Advertisement

loading

Summary of Contents for Fujitsu FTR-K2G Series

  • Page 1 FTR-K1 SERIES POWER RELAY 1 POLE - 20A, 3.0mm contact gap FTR-K2G Series n FEATURES Contact gap min. 3.0mm Full disconnection 1 Pole, 1 Form A Maximum inrush current 120A (TV-8) (UL) (VDE) High insulation Reinforced insulation Insulation distance between coil and contact: - Clearance min.
  • Page 2 FTR-K2G SERIES FTR-K1 SERIES n SPECIFICATION Item FTR-K2GAK ( ) T Contact Configuration 1 form A (SPST-NO) Data Construction Single Material AgSnO2 Resistance (initial) Maximum 100mOhm at 1A, 6VDC Contact rating (resistive) 20A / 250VAC Max. carrying current *¹ Max. inrush current 120A / 250VAC Max.
  • Page 3: Safety Standards

    FTR-F4 SERIES FTR-K2G SERIES FTR-K1 SERIES n COIL RATING Rated Coil Must Operate Must Release- Coil Coil Resistance Max. Coil Voltage Rated Power Voltage Voltage Voltage Code +/- 10% (Ohm) (VDC) (mW) (VDC) (VDC) * (VDC) * 3.25 0.25 10.2 5.85 0.45 15.3...
  • Page 4 FTR-F4 SERIES FTR-K2G SERIES FTR-K1 SERIES n CHARACTERISTIC DATA n REFERENCE DATA...
  • Page 5 FTR-F4 SERIES FTR-K2G SERIES FTR-K1 SERIES n DIMENSIONS Dimensions Schematics (BOTTOM VIEW) PC board mounting hole layout (BOTTOM VIEW) Unit: mm...
  • Page 6: General Information

    RoHS Compliance and Lead Free Information 1. General Information All signal and power relays produced by Fujitsu Components are compliant with RoHS directive 2002/95EC including amendments. Cadmium as used in electrical contacts is exempted from the RoHS directives on October 21st, 2005.
  • Page 7 ©2010 Fujitsu Components Europe B.V. All rights reserved. All trademarks or registered trademarks are the property of their respective owners. The contents, data and information in this datasheet are provided by Fujitsu Component Ltd. as a service only to its user and only for gen- eral information purposes.