Table of Contents

Advertisement

Available languages

Available languages

installation instructions
[] WINDOW REQUIREMENTS
• These instructions are for a standard double-hung
window. You will need to modify them for other types
of windows.
• All supporting parts must be secured
to firm wood, masonry or metal.
• The electrical outlet must be within reach of the
power cord.
• Follow the dimensions in the table and illustration
for your model.
!
18.5"
26"- 41"
(With accordion panels)
1
STORMWINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep it
from draining properly.
To adjust for this, attach a piece of wood to the sill.
WOOD PIECES
WIDTH:2"
LENGTH:Long enough to fit inside the window
frame.
THICKNESS: The top of the wood should be 1/2"
higher than the top of the storm window frame or
the vinyl frame.
Attach securely with nails or screws provided by the
installer.
1/2" higher
than storm
window
frame
Storm window
frame
1/2" higher
than vinyl frame
_ (on some windows)
_
Wood
-
r_
Vinyl frame
I
D PREPARETHE AiR CONDiTiONER
r_
Pull the top of the front panel out and down.
Remove the filter. Remove the front panel by
lifting up at an angle.
r_
Remove
the four front
screws.
Save them
for reinstalling
the front
housing.
rCl Grasp
the lower
corners
of the grille
while
pressing
in on the case sides with
your
finger
tips. Pull out to release
and lift it up.
NOTE:
Do not pull the bottom
edge
toward
you more
than 3" or you may
damage
the tabs of the grille.
t
t
@
When
the front
grille
is removed
the
control
panel will
still be attached
by
a harness.
Turn
the grille
around
so
you can see the back side of the grille.
Remove
the 2 screws
to separate
the
control
panel
housing
from
the grille.
NOTE: Be sure to save these screws.
You will
need them later in the installation.
RemoveScrews
9

Advertisement

Table of Contents
loading

Table of Contents