Download Print this page

Craftsman 919.727321 Owner's Manual page 8

Permanently lubricated tank mounted air compressor
Hide thumbs Also See for 919.727321:

Advertisement

Installing Wheels, Handles,
Rubber Foot
Strip
THE WHEELS AND HANDLE DO NOT PROVIDE
ADEQUATE
CLEARANCE, STABILITY OR SUP-
PORT FOR PULLING THE UNIT UP AND DOWN
STAIRS OR STEPS. THE UNIT MUST
BE LIFTED, OR PUSHED
UP A RAMP.
1.
Attach the handle to the compressor
saddle by
inserting the handle
inside
the compressor
saddle
and lining up the two bolt holes on each side.
Install
the four screws,
two on each side. Tighten securely.
2.
Install one shoulder
bolt and one nut for each wheel.
Tighten securely. The compressor
will sit level if the
wheels
are properly
installed.
3.
Clean and dry underside
of air tank leg opposite
wheels.
Remove the protective
paper strip from the
adhesive
backed rubber foot strip.
Attach the rubber
foot strip to the bottom
of leg. Press firmly into place.
Location
of the Air Compressor
Locate the air compressor
in a clean, dry and well venti-
lated area.
The air filter must be kept clear of obstruc-
tions which could reduce
air delivery
of the air compres-
sor.
The air compressor
should
be located
at least 12"
away from the watt or other obstructions
that will interfere
with the flow of fresh intake and cooling air.
Lubrication
and Oil
This unit needs no lubrication
or oiling.
Grounding
Instructions
RISK OF ELECTRICAL SHOCK.
In the event of a
short circuit, grounding reduces the risk of shock
by providing an escape wire for the electric
current. This air compressor must be properly
grounded.
This portable air compressor
is equipped
with a cord hav-
ing a grounding
wire with an appropriate
grounding
plug
The plug must be used with an outlet that has been in-
stalled
and grounded
in accordance
with all local codes
and ordinances
The outlet must have the same configu-
ration as the plug
DO NOT USE AN ADAPTER.
Inspect the plug and cord before each use
Do not use if
there are signs of damage
IMPROPER
GROUNDING
CAN
RESULT
IN
ELECTRICAL
SHOCK.
Do not modify
the plug that has been provided.
If it
does
not fit the available
outlet,
the correct
outlet
should
be installed
by a qualified
technician.
If repairing
or replacing
cord or plug, the grounding
wire
must be kept separate
from the current-carrying
wires.
Never connect
the grounding
wire to a flat blade plug
terminal. The grounding
wire has insulation
with an outer
surface that is green with or without
yellow stripes.
If these grounding
instructions
are not completely
under
stood,
or if in doubt
as to whether
the compressor
is
properly
grounded,
have the installation
checked
by a
qualified
electrician.
120 Volt Models
240 Volt Models
White
15 AMP PLUG
OUTLET
_---r_GROUNDED
GROUNDING
_)f
PIN
20 AMP PLUG
GROUNDING
J_
PIN
OUTLET
Voltage and Circuit Protection
Refer to page 5 (Specification Chart)
for the voltage and
circuit
protection
requirements
of your compressor.
Use
only a fuse or circutt breaker
that is the same rating as
the branch
circuit
the air compressor
is operated
on. If
the compressor
is connected
to a circuit
protected
by
fuses,
use only dual element
time delay fuses.
Refer to Parts List Manual
for your compressor.
Certain
air compressor
models
can be operated
on a 15 amp
circuit
if:
1. Voltage supply to circuit is normal.
[)20015
14evl
3/22/00
8 I
ENG

Advertisement

loading