Belt Guide Adjustment; Pump Drive Belt Tension; Hydro Drive Linkage Adjustment - Exmark VIKING HYDRO Operator's Manual

Hide thumbs Also See for VIKING HYDRO:
Table of Contents

Advertisement

Figure 18
Shown with Blades Disengaged
1. Blade Brake Rod
2. Spring Mounting Bolts
4. Check the distance between the spacer and the
nut at the end of the blade brake rod. The
distance should be between 1/8 inch (.32 cm) and
3/16 inch (.47 cm) (see Figure 18).
5. Engage the PTO and check to make sure the
blade brake pad clears the sheave.

Belt Guide Adjustment

1. Stop engine and wait for all moving parts to stop.
Engage parking brake. Remove key or spark plug
wire(s).
2. Engage the PTO.
3. Check belt guide under the engine deck for proper
adjustment (see Figure 19 and Figure 20). Adjust
as necessary.
Figure 19
36 inch Belt Guide Location
(Viewed from underneath the engine deck)
1. 1 1/4 inch (3.1 cm)
2. 1/4 inch (.64 cm)
clearance
3. 1/8 inch to 3/16 inch
(.32–.47 cm)
3. End of slot
48 inch Belt Guide Location
(Viewed from underneath the engine deck)
1. 1 3/8 inch (3.5 cm)
2. 1/4 inch (.64 cm)
clearance

Pump Drive Belt Tension

Self-tensioning - No adjustment necessary.
Hydro Drive Linkage
Adjustment
• Adjust Speed Control Linkage and Neutral
Safety Switch:
1. Stop engine and wait for all moving parts to
stop. Engage parking brake. Remove key or
spark plug wire(s).
2. Move the speed control lever (located on
the console) to the full forward position and
check the orientation of the tabs on the ends
of the speed control crank (see Figure 21).
These tabs should be pointing straight down
at the 6 o'clock position or slightly forward.
Adjust the threaded yoke at the bottom of the
speed control linkage (see Figure 21) until the
tabs are positioned correctly.
33
Maintenance
Figure 20
3. End of slot