If door is left open (approximately) two minutes, unit will stop feeding and fire will go out.
This stove has an induced draft system and is designed to operate continuously, as frequent
shutdown is not required. The setting of the "Heat Range" touch pad will control the heat output
and the amount of fuel the unit will burn (see "Control Board" section and Illustration 4). Note: This
stove is using solid fuel and will not restart automatically.
* NOTE: Blower Speed will automatically be adjusted to the desired Heat Range that you select.
Caution - Never use gasoline, lantern fuel, charcoal lighter fluid, diesel fuel, or any other
flammable liquid to start the fire.
When first starting your corn/pellet stove, place approximately one (1) cup of hardwood pellets in
the fire pot. Place a small amount of starter gel or fire starter on top of the pellets and light, leaving
the door cracked slightly for the first 2 minutes. After the first two minutes, close the door and press
the "ON" button located on the Control Panel.
The Heat Range and Blower Speed will automatically be set to setting "5," to ensure that proof of
fire is detected. During the 20 minute start-up period the user can set the controls to a desired heat
setting, and after the 20 minute start-up the unit will operate at that user setting.
On the "first fire" (the first time you burn the unit), the Control Panel should be set at a "5"
NOTE:
Heat Range and "5" Blower Speed for at least 3 hours to allow the unit to "cure" as the oils
from the manufacturing process burn off. Windows and doors in the home should be opened
to help ventilate as these oils burn off.
If the unit does not start,
NOTE:
the unit does not start or maintain a fire, you will receive an
Speed window of the Control Board. If this occurs, wait until unit has cooled completely down
and repeat these steps.
If the fuel is not feeding correctly, the feed auger could possibly be misaligned due to factors
such as rough handling during shipping. If you suspect your feed auger is misaligned, call Customer
Service at (800) 245-6489.

OPERATING INSTRUCTIONS

CAUTION: DO NOT OPERATE WITH THE DOOR OPEN.
Do not burn trash (paper bags, etc.) in this unit.
START- UP PROCEDURES
try to restart the unit until it has cooled completely down. If
DO NOT
FUEL NOT FEEDING CORRECTLY
in the Heat Range and Blower