INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
UNVENTED ROOM HEATER
MODELS

INSTALLATION AND OPERATING INSTRUCTIONS

England's Stove Works highly recommends the use of smoke detectors and
Carbon Monoxide detectors with any hearth product, including this unit. Follow all
manufacturer's instructions when using smoke or Carbon Monoxide detectors.
This appliance may be installed in an aftermarket, permanently located, manufactured
This appliance is only for use with the type of gas indicated on the rating plate. This
Warning: Improper installations, adjustments, alterations, service or maintenance can
cause injury, property damage, or loss of life; refer to this manual. A qualified installer,
service agency or the gas supplier must perform installation and service.
WARNING: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE
OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR
LOSS OF LIFE.
•Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance.
A QUALIFIED INSTALLER, SERVICE AGENCY OR GAS SUPPLIER MUST
PERFORM INSTALLATION AND SERVICE. CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NEVER BE PLACED ON OR NEAR THE APPLIANCE.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
This is an unvented gas-fired heater. It uses air (oxygen) from the room
in which it is installed. Provisions for adequate combustion and
ventilation air must be provided. Refer to Installation Instructions.
Rev. 10/08
:
26-GULP
60-SHULP
60-TRULP
26-GUHLP
60-SHUHLP
60-TRUHLP
(mobile home), where not prohibited by code.
appliance is not convertible for use with other gases.
→WHAT TO DO IF YOU SMELL GAS←
•Do not try to light any appliance.
•If you cannot reach your gas supplier, call the fire department.
26-GUNG
60-SHUNG
60-TRUNG
26-GUHNG
60-SHUHNG
60-TRUHNG
instructions.

Advertisement

Table of Contents
loading

Summary of Contents for England's Stove Works 26-GUHLP

  • Page 1: Installation And Operating Instructions

    Provisions for adequate combustion and ventilation air must be provided. Refer to Installation Instructions. Rev. 10/08 26-GULP 26-GUNG 60-SHULP 60-SHUNG 60-TRULP 60-TRUNG 26-GUHLP 26-GUHNG 60-SHUHLP 60-SHUHNG 60-TRUHLP 60-TRUHNG (mobile home), where not prohibited by code. •Do not try to light any appliance. instructions.
  • Page 2 Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself” store.
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS 1. Minimum inlet gas supply pressure must be 5.5” w.c. for natural gas and 11” w.c. for propane (LP) gas for the purpose of adjustment. Maximum gas supply pressure must not exceed 10.5” w.c. with natural gas, or 14” w.c. with propane (LP) gas. Use the correct gas type for your appliance —...
  • Page 4: Minimum Clearances To Combustibles

    → TYPE OF GAS MAX. INPUT MIN. INPUT MANIFOLD PRESSURE M/FOLD PRESSURE LOW MIN. INLET PRESSURE MIN. SUPPLY PRESSURE MAX. SUPPLY PRESSURE ORIFICE SIZE MINIMUM CLEARANCES TO COMBUSTIBLES England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit.
  • Page 5 This heater is equipped with a PILOT LIGHT (OXYGEN DEPLETION SENSOR) SAFETY SYSTEM designed to turn off the unit if there is not sufficient fresh air available. If the appliance keeps shutting off, have it serviced. DO NOT TAMPER WITH THE PILOT LIGHT (ODS) SAFETY SYSTEM! Keep the burner and control compartment clean.
  • Page 6: Log Assembly

    “WARNING: If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Ventilation, or applicable local codes.”...
  • Page 7: Operating Instructions

    IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. This unit has a piezo ignition pilot. When lighting the pilot, follow these instructions exactly. BEFORE LIGHTING, smell around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
  • Page 8: Maintenance Instructions

    MAIN BURNER IGNITION 1) Upon lighting, release knob and turn further counterclockwise ← to “ON” position (both pilot and gas flow). 2) Turn on all electric power to appliance. TO TURN GAS OFF TO APPLIANCE 1) Set thermostat to the lowest setting. 2) Turn off all electric power to the appliance if service is to be performed.
  • Page 9: Parts List

    Model 26-GUNG/26-GULP and 26-GUHNG/26-GUHLP Model 60-SHUNG/60-SHULP and 60-SHUHNG/60-SHUHLP Model 60-TRUNG/60-TRULP and 60-TRUHNG/60-TRUHLP Exploded View No. Part No.* GUV-3211 GUV-3033 GUV-3053 NOTE: The following Valve/Burner assemblies are for GU, SHU and TRU models GUV-30LP GUV-30NG NOTE: The following Valve/Burner assemblies are for GUH, SHUH and TRUH (Hearth-adaptable models)
  • Page 10: Troubleshooting Guide

    TROUBLE SHOOTING GUIDE ITEMS IN THIS GUIDE MARKED WITH AN ASTERISK (*) SHOULD ONLY BE PERFORMED BY A LICENSED GAS FITTER OR EQUIVALENT. WARNING Turn off and let the unit cool before servicing. Only a qualified service person should service or repair this unit. PROBLEM Ignitor electrode positioned wrong.
  • Page 11 PROBLEM Pilot will not stay lit. Altitude is above 4000 ft.; ODS sensor requirement for air not satisfied.→ Defective thermopile.→ Pilot orifice may be clogged.→ Defective valve magnet.→ “ODS” pilot lights, but flame dies when control knob is released. Control knob not fully pressed in.→ Control knob not pressed in long enough.→...
  • Page 12: Warranty Information

    WARRANTY INFORMATION Model #__________________________________ Serial #__________________________________ Date Purchased ___________________________ Manufacture Date _________________________ Purchased From (Dealer) ____________________ NOTE: Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty.
  • Page 13: Dealer Information

    WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ Telephone _______________________________________________________ Email Address ___________________________________________________ DEALER INFORMATION Purchased From (Dealer) ___________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ UNIT INFORMATION – (Please be sure to refer to sticker on back of manual or box to complete this section) Model Number _____________________ Purchase Date _________________...