Carrier 38BNE018-036 Owner's Manual page 9

Cooling only and heat pump duct-free high wall systems

Advertisement

Available languages

Available languages

System
Operation
Check
List -- The items outlined
in the tbllowing list will help to assure proper system operation:
• Be sure unit is connected directly to electrical supply.
• Replace both remote control batteries at the same time
when the Low Battery symbol appears.
• Point the remote control toward the unit display panel
when transmitting a command.
• Place the remote control in a location where there is a
direct line for transmission of data to the unit.
• Select a moderate temperature setting. Extreme tempera-
tures waste electricity.
• Keep doors and windows closed while unit is operating.
• Close air vents in unoccupied rooms to save electricity.
• Contact an authorized service representative ifa problem
arises that cannot be easily resolved.
• Do not perform cleaning or maintenance activities while
unit is on.
• Keep remote control out of direct sunlight and heat.
• Keep display panel on unit away fiom direct sunlight and
heat as this may interfere with relnote control transmissions.
• Do not block air intakes and outlets on the indoor or
outdoor units.
DIP Switch Settings-
The relnote control contains
seven DIP switches, located in the battery compartment, two of
which control special system characteristics. See Fig. 15. The
DIP switch default positions are set according to the model air
coMitioner installed, as per the following table.
SWITCH
I
1
2
3
4
5
6
7
POSITION
I ON
OFF
OFF
OFF
OFF
ON
OFF
Switch No. 3 should be set as follows:
OFF (default)
When only one air conditioner is installed
in the room.
ON
When there are tvxs_air conditioners with relnote
controllers installed in the room, in one of the relnote control-
lers this switch must be in the ON position. To activate the new
switch setting, simultaneously press the MODE and ROOM
buttons.
Switch No. 4 should be set as follows:
OFF
Displays temperature in °C, with a 24-hour clock
format.
ON
Displays temperature in °E with a 12-hour clock
(PM indictor) tbnnat.
To operate the special systems characteristics:
1. Relnove the batteries.
2.
Set the DIP switches to the required positions.
3. Wait approximately 2 minutes and return batteries to
proper position.
Energy
Saving
Recommendations
-- The follow-
ing recolrnnendations will add greater efficiency to the duct
l?ee system:
• Select a comfortable
thermostat setting and leave it at
chosen setting. Avoid continually raising and lowering
the setting.
• Keep unit filter clean. Frequent cleaning may be neces-
sary depending on indoor air quality.
• Use drapes, curtains or shades to keep direct sunlight
froln heating room on very hot days.
• Do not obstruct front grille air intake on front panel.
• Turn on air conditioning before indoor air becomes too
uncomfortable.
ON
OFF
/
1234567
Fig. 15 -- DIP Switch Location in Remote Control