RaceAmerica 3220 Series Owner's Manual

Soap box derby finish differential & et timer

Advertisement

Quick Links

The Leader in Event Critical Timing Electronics
Model 3220 Series
Timer SBD
Soap Box Derby
Finish Differential & ET Timer
Owner's Manual
Rev M
RaceAmerica Corporation
P.O. Box 3469
Santa Clara, CA 95055-3469
USA
(408) 988-6188
http://www.raceamerica.com
info@raceamerica.com
Copyright 2008 RaceAmerica Corporation.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 3220 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for RaceAmerica 3220 Series

  • Page 1 The Leader in Event Critical Timing Electronics Model 3220 Series Timer SBD Soap Box Derby Finish Differential & ET Timer Owner’s Manual Rev M RaceAmerica Corporation P.O. Box 3469 Santa Clara, CA 95055-3469 (408) 988-6188 http://www.raceamerica.com info@raceamerica.com Copyright 2008 RaceAmerica Corporation.
  • Page 2: Table Of Contents

    RaceAmerica Model 3220 Timer SBD Table of Contents LIMITED WARRANTY ........................3 PACKAGE COMPONENTS .........................4 POWER REQUIREMENTS ........................4 PRODUCT SPECIFICATIONS ......................4 AVAILABLE OPTIONS ........................4 THEORY OF OPERATION ........................4 SET-UP STEPS - 3220 SERIES ......................5 Cabling Diagram ..........................5 Power On/Self-Test ...........................5 Alignment Mode ..........................6 Configuration ............................7 TIMING A RUN ............................7 Finish Differential ..........................7...
  • Page 3: Limited Warranty

    RaceAmerica Model 3220 Timer SBD RACE MERICA T i m i n g S y s t e m s LIMITED WARRANTY To the original purchaser of this RaceAmerica product, RaceAmerica warrants it to be in good work- ing order for a period of ninety (90) days from the date of purchase from RaceAmerica or an authorized RaceAmerica distributor.
  • Page 4: Package Components

    RaceAmerica Model 3220 Timer SBD PACKAGE COMPONENTS 6070B Carry/Storage Case 6502A AC Power Adapter Each 3220 Series Timer SBD timing system 3120A AXWARE Derby Software package includes: 3120B AXWARE Derby + Race Management S/W 1 - 3220D Series Console Unit 3120C AXWARE Derby + Race 1 - IR Beam Emitter Model 5042 Management (AASBD) S/W...
  • Page 5: Set-Up Steps - 3220 Series

    RaceAmerica Model 3220 Timer SBD SET-UP STEPS - 3220 SERIES Picture shows one unit from the top and one unit from the bottom. STEP 1 - Familiarize yourself with the components pictured in this manual and how they interconnect. Track Sensor Interconnect Cable is configured for connection between the a Sensors, Win Lights Model 5042 Model 5140...
  • Page 6: Power On/Self-Test

    RaceAmerica Model 3220 Timer SBD Emitter Sensor The Emitter throws a spot light like beam of infrared light; the Sensor should be aligned near the center of the beam for optimal reception and alignment. Interconnect Cable to the Timer Console and the ALIGNMENT MODE Track Sensors through the opening in the back of the Foam Stand.
  • Page 7: Configuration

    RaceAmerica Model 3220 Timer SBD until the alignment starts counting determines the enter the system configuration mode, the console displays [-Port-] [-Print] which sends timeslip maximum vertical detection angle. Once these extremes are established, position the Beam Emit- data to the printer port. Repeated presses of the [#] ENTER key cycle the lower display to Display ter in the center of the left/right detection angle [-diSP-] which will send ET times to scoreboards.
  • Page 8: Timing A Run

    RaceAmerica Model 3220 Timer SBD TIMING A RUN - Finish Differential printout and in the data transmitted to PC capture software. To enter a racer number, press the [9] CAR# button on the keypad to view the existing Before timing a run, it may be desireable to entries;...
  • Page 9: Options

    RaceAmerica Model 3220 Timer SBD SYSTEM OPTIONS PRINTER OPTION Several options (Elapsed Time (ET), Printer, Connect the timeslip printer interface cable to Digital Display or PC) can be connected by a the 3220 Timer SBD using the PRINTER PORT RS232 cable connection up to 100 feet or by a on the console.
  • Page 10: Maintenance

    RaceAmerica Model 3220 Timer SBD MAINTENANCE WIN LIGHT ASSEMBLY The 3220 Series Console, Beam Emitter, and The win lights are assembled by screwing Track Sensors do not require any maintenance. the post into the base and then attaching the Win To insure uninterrupted operation on raceday, Light with a 1/4-20 bolt at the top of the post - it is suggested to keep track of battery usage hours...
  • Page 11: Foam Stand Assembly

    RaceAmerica Model 3220 Timer SBD 7540C - Foam Stand Assembly Instructions Emitter Base Foam Top Foam Sensor Assembly Components ‘AA’ Battery Emitter (5040B, 5050B & 5058B) 1. Install batteries and turn on the Emitter. 2. Separate the Base of the Foam Stand from the Top. 3.
  • Page 12 RaceAmerica Model 3220 Timer SBD TIMESLIP HEADER The following table lists the codes for each The 3220 Console allows custom timeslip character (note: upper and lower case letters have header input for four lines of up to 39 characters different codes). Use the worksheet on the next each to print at the top of each timeslip.
  • Page 13 RaceAmerica Model 3220 Timer SBD Line Line Line Line...