Download Print this page

Lightolier Lytespan 83ED17RWF Specification page 2

Track lighting system

Advertisement

Page 2 of 2
AIMING ANGLE:
L
Beam Length
W Beam Width
C
Distance to center beam
L and W are the outer points where the candle power drops
to 50% of the maximum. FC are the initial footcandles at the
center of the beam.
Lamp data shown is typical. Consult lamp manufacturers for
availability and performance.
Wide Flood -
When used in Metallics
LAMP:
Beam Spread
CBCP
(To 50% CBCP)
4,312
52˚ X 52˚
For 50W: Multiply values by .69
Rated Lamp Life 10,000
For 100W: Multiply values by 1.5
Rated Lamp Life 12,500
Wide Flood -
When used in 8307U and 8317U Luminaires. Data for 70W ED17 Master Color Ceramic Metal Halide Philips (Clear) Lamp for Enclosed Luminaires
LAMP:
Beam Spread
CBCP
(To 50% CBCP)
2,676
70" X 70"
52˚ X 52˚
For 50W: Multiply values by .69
Rated Lamp Life 10,000
For 100W: Multiply values by 1.5
Rated Lamp Life 12,500
*Exceeds useable limits.
Lytespan
®
Track Lighting System
0° Horizontal Aiming
D
Distance
A
Aiming Angle
FC Footcandles
®
Series Luminaires. Data for 70W ED17 Master Color Ceramic Metal Halide Philips Protected (Clear) Lamp
0˚ Horizontal Aiming
30˚ Horizontal Aiming
Rated
D
FC
L
W
Life (Hrs.)
6'
120
5.9'
5.9'
10,000
8'
67
7.8'
7.8'
10'
43
9.8'
9.8'
12'
30
11.7'
11.7'
0˚ Horizontal Aiming
30˚ Horizontal Aiming
Rated
D
FC
L
W
Life (Hrs.)
6'
74
8.4'
8.4'
10,000
7'
55
9.8'
9.8'
8'
42
11.2'
11.2'
9'
33
12.6'
12.6'
Metal Halide ED-17 Reflector Wide Flood
30° Horizontal Aiming
30˚ Vertical Aiming
D
C
FC
L
W
D
C
5'
2.9'
112
7.1'
5.6'
3'
5.2'
7'
4.0'
57
9.9'
7.9'
4'
6.9'
5'
8.7'
9'
5.2'
35
12.7'
10.1'
6'
10.4'
11'
6.4'
23
15.5'
12.4'
30˚ Vertical Aiming
D
C
FC
L
W
D
C
2'
3.5'
6'
3.5'
48
13.4'
9.7'
3'
5.2'
7'
4.0'
35
15.6'
11.3'
4'
6.9'
8'
4.6'
27
17.9'
12.9'
5'
8.7'
9'
5.2'
21
20.1'
14.6'
Job Information
Lightolier
a Genlyte Thomas Company
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division) • D0104
83ED17RWF
30° Vertical Aiming
45° Vertical Aiming
45˚ Vertical Aiming
FC
L
W
D
C
FC
5'
5'
656
645
2.4'
1.2'
7'
7'
335
363
3.2'
1.5'
9'
9'
203
232
4.0'
1.9'
11'
11'
136
161
4.8'
2.3'
45˚ Vertical Aiming
FC
L
W
D
C
FC
84
*
5.6'
3'
3'
105
16.5'
37
*
8.4'
4'
4'
59
22.0'
21
*
11.2'
5'
5'
38
27.5'
13
*
14.0'
6'
6'
26
33.0'
Type:
www.lightolier.com
L
W
1.9'
1.4'
2.7'
1.9'
3.5'
2.5'
4.3'
3.0'
L
W
5.9'
7.9'
9.9'
11.9'

Advertisement

loading