Hitachi CP-D10 User Manual page 102

Hide thumbs Also See for CP-D10:
Table of Contents

Advertisement

Communicaion settings
1. Protocol
19200bps,8N1
2. Command format
Byte Number
Command
Action
<SET>Change setting to
desired value [(cL)(cH)]
by [(eL)(eH)].
<GET>Read projector
internal setup value [(bL)
(bH)] .
<INCREMENT>
Increment setup value
[(bL)(bH)] by 1.
<DECREMENT>
Decrement setup value
[(bL)(bH)] by 1.
<EXECUTE> Run a
command [(bL)(bH)].
[Header code] [Packet] [Data size]
Set [BEh, EFh, 03h, 06h, 00h] to byte number 0 ~ 4.
[CRC flag]
For byte number
[Action]
Set functional code to byte number 7, 8.
<SET> = [01h, 00h], <GET> = [02h, 00h], <INCREMENT> = [04h, 00h]
<DECREMENT> = [05h, 00h], <EXECUTE> = [06h, 00h]
Refer to the Communication command table
[Type] [Setting code]
For byte number
11).
(
("h" shows hexadecimal)
0
1
2
Header
Header
code
Packet
L
H
BEh EFh
03h
5, 6,
RS-232C Communication command table (
refer to
9 12
RS-232C Communication command table
, refer to
RS-232C Communication (continued)
3
4
5
6
Data
CRC
size
flag
L
H
L
H
(aL) (aH) 01h 00h (bL) (bH) (cL) (cH)
(aL) (aH) 02h 00h (bL) (bH) 00h 00h
06h 00h
(aL) (aH) 04h 00h (bL) (bH) 00h 00h
(aL) (aH) 05h 00h (bL) (bH) 00h 00h
(aL) (aH) 06h 00h (bL) (bH) 00h 00h
above).
(
7
8
9
10
11
Data
Action
Type
L
H
L
H
12
Setting
code
L
H
11).
9

Advertisement

Table of Contents
loading