Download Print this page

Lightolier Pendalyte 4073U Specification page 3

16" pendant

Advertisement

Page 3 of 4
Application Data
Multiple Units (32W Triple Tube CFL)
Spacing
Height
on
to Lighted
Center
Plane
6'
6'
12'
6'
8'
12'
6'
10'
12'
Based on 60" x 60" room with 80% ceiling cavity, 50% wall and 20% floor reflec-
tances. Height is from bottom of fixture to lighted plane.
Spacing Ratio = 2.8 
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • O1009
Specification Decorative Pendalyte
Initial
Watts
Foot-
Per
candles
Sq. Ft.
64
1.00
55
36
0.56
31
23
0.36
20
32W Triple Tube CFL
Illuminance (FC) Multipliers
For Compact
For Incandescent:
Fluorescent:
100 Watt = 0.7
26 Watt = 0.7
150 Watt = 1.2
42 Watt = 1.3
Coefficients Of Utilization 
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 
70 
% WALL REFLECTION
50  30 
10 
50 
30  10 
50 
20% FLOOR CAVITY REFLECTANCE
Coefficients Of Utilization 
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 
70 
% WALL REFLECTION
50 
30 
10 
50 
30 
10 
50 
20% FLOOR CAVITY REFLECTANCE
Job Information
  4073U
16" Pendant
For Metal
Halide:
100 Watt = 3.5
150 Watt = 5.2
32W Triple Tube CFL
50 
30 
10 
30 
10 
50 
30 
10 
50  30 
10 
150W ED17 MH
50 
30 
10 
30  10 
50  30 
10 
50 
30  10 
Type:
0
0
0
0

Advertisement

loading