Miele DA 5321 W Operating And Installation Manual

Ventilation system

Advertisement

Operating and Installation
Instructions
Ventilation System
DA 5321 W
DA 5381 W
DA 5391 W
en - US, CA
To prevent accidents
and appliance damage,
read these instructions
before
installation or use.
M.-Nr. 07 901 910

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 5321 W

  • Page 1 Operating and Installation Instructions Ventilation System DA 5321 W DA 5381 W DA 5391 W en - US, CA To prevent accidents and appliance damage, read these instructions before installation or use. M.-Nr. 07 901 910...
  • Page 2: Table Of Contents

    Contents IMPORTANT SAFETY INSTRUCTIONS....... . . 3 Functional description ..........7 Guide to the Ventilation System .
  • Page 3: Important Safety Instructions

    Use this appliance only in the manner intended by the manufacturer. Read these instructions carefully If you have questions, contact Miele. before installing or using the b) Before servicing or cleaning the Ventilation System. appliance, switch power off at the...
  • Page 4 IMPORTANT SAFETY INSTRUCTIONS d) Before connecting the appliance to the power supply make sure that the ,WARNING voltage and frequency listed on the data plate correspond with the TO REDUCE THE RISK OF A household electrical supply. COOKTOP GREASE FIRE: This data must correspond to prevent appliance damage.
  • Page 5 IMPORTANT SAFETY INSTRUCTIONS ,WARNING Do not allow children to play with or operate the appliance or its controls. TO REDUCE THE RISK OF Supervise its use by the elderly or INJURY TO PERSONS IN THE infirm. EVENT OF A COOKTOP Always turn on the hood when using GREASE FIRE, OBSERVE THE the cooktop to prevent damage from...
  • Page 6 IMPORTANT SAFETY INSTRUCTIONS Installation g) Do not install this hood over cooktops that burn solid fuel. ,WARNING h) Provided a larger distance is not TO REDUCE THE RISK OF given by the manufacturer of the FIRE, ELECTRIC SHOCK, OR cooktop, follow the minimum safety distances between a cooktop and the INJURY TO PERSONS, bottom of the hood given in the...
  • Page 7: Functional Description

    Functional description The hood offers two modes of operation: Air extraction Recirculation mode The air is drawn in and cleaned by the Air is drawn through the grease filters grease filters and directed outside. and an active charcoal filter. The filtered air is then recirculated back into The hood comes equipped with a the kitchen through a vent at the top of...
  • Page 8: Guide To The Ventilation System

    Guide to the Ventilation System...
  • Page 9 Guide to the Ventilation System Chimney extension Grease filter button The indicator next to the grease filter Chimney button lights when the grease filters need to be cleaned. This button is also Canopy used: – to reset the grease filter timer after Charcoal filter cleaning the grease filters (see "Cleaning and Care").
  • Page 10: Operation

    Operation Turning on the fan Automatically switching back the Intensive power level The intensive level "4" can be programmed to automatically switch back to level "3" after 10 minutes. ^ Press the On/Off button. ^ Turn the fan and the lights off. Selecting the power level ^ Press and hold the Delayed Shut down button for 10 secs.
  • Page 11 Operation If the power level indicators flash the Fan performance automatic switch back is not activated. The maximum air flow capacity is 625 cfm. Factors such as narrow duct diameter and bends will affect this value. Level 1 operates at 40% capacity ^ To activate the automatic switch back Level 2 operates at 60% capacity press the "+"...
  • Page 12: Delayed Shut Down

    Operation Delayed Shut Down Turning off the fan If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue ^ Press the On/Off button to turn the running for either 5 or 15 minutes.
  • Page 13: Turning The Lighting On/Off

    Operation Turning the lighting On/Off Dimming the lighting The overhead lighting can be turned on The brightness of the lighting can be and off independently from the fan. adjusted. ^ While the lighting is turned on, press the light button. The lighting will dim until the button is released.
  • Page 14: Filter Timers

    Operation Filter timers Checking the filter timers ^ Press the On/Off button to turn the Grease filters fan on. A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filters must then be cleaned.
  • Page 15: Reprogramming The Timers

    Operation Reprogramming the timers The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40, or 50 hours. The lit indicator shows the programmed – A time of 20 hours should be time: programmed in kitchens with 1st indicator from the left...
  • Page 16 Operation Reprogramming the charcoal filter timer The active charcoal filter can only be used in recirculation mode and cannot The lit indicator shows the programmed be used to exhaust fumes. time: The charcoal filter timer is not preset. 1st indicator from the left = 20 hours Before using the hood in recirculation 2nd indicator from the left = 30 hours...
  • Page 17: Cleaning And Care

    Cleaning and Care ,WARNING Avoid: TO REDUCE THE RISK OF – cleaning agents containing soda, FIRE, ELECTRIC SHOCK, OR acids or chlorides, INJURY TO PERSONS, – abrasive cleaning agents OBSERVE THE FOLLOWING: e.g. powder or cream cleansers, – abrasive sponges, e.g. pot scourers Before cleaning or servicing the or sponges which have been hood, disconnect it from the power...
  • Page 18: Grease Filters

    (grease, dust, etc). Use a wash program with a max. temperature of 150°F (65°C). In a Miele dishwasher use the "Normal" program. Use the recommended amount of dishwasher detergent. Overuse could The grease filters should be cleaned destroy the filter.
  • Page 19: Active Charcoal Filter

    Replacement active charcoal filters ^ Insert the charcoal filter. can be ordered from Miele. Before using: ^ Remove the grease filters to access ^ Program the charcoal filter timer, see the charcoal filter. See "Cleaning and "Operation / Reprogramming the...
  • Page 20: Changing The Light Bulbs

    Cleaning and Care Changing the light bulbs ,WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, and can burn your hands.
  • Page 21: After Sales Service

    Miele’s Service department, Extended Service Contracts offered by other providers for Miele products will not be recognized by Miele. Our goal is to prevent unauthorized (and untrained) service personnel from working on your Miele products, possibly doing further damage to them, you and/or your home.
  • Page 23: Installation Instructions

    Installation Instructions Read these instructions and the "Important Safety Instructions" before installing this ventilation system. The installation steps are described in the enclosed "Installation Diagram". Leave these instructions with the appliance for the consumer/user. Information is subject to change. Please refer to our website to obtain the most current product specification, technical &...
  • Page 25: Caring For The Environment

    Caring for the environment Disposal of packing material Disposal of an old appliance The cardboard box and packing Old appliances may contain materials materials protect the appliance during that can be recycled. Please contact shipping. They have been designed to your local recycling center about the be biodegradable and recyclable.
  • Page 26: Appliance Dimensions

    Appliance dimensions 1) Air extraction mode 4) and 5) Installation area Wall/ceiling area respectively for vent 2) Recirculation mode hole and outlet installation. 3) Air extraction vent installed upwards For recirculation mode only 4) and only outlet installation. Vent hole 6" (150 mm) with reducing collar 5"...
  • Page 27 Appliance dimensions Cut out area in wall or ceiling for Standard unit height (H): entrance of 6" (150 mm) Air Extraction ..29 " - 41 " ductwork or 5" (125 mm) ....(745 - 1055 mm) ductwork with a reducing collar.
  • Page 28 Do not install this exhaust hood over cooktops burning solid fuel. Provided a larger distance is not given by the manufacturer of the cooktop, follow the minimum safety distances between a cooktop and the bottom of the hood: Miele Cooktops Non-Miele Cooktops Electric Cooktops 24"...
  • Page 29: Plywood Backing

    Plywood backing ^ Find the studs to the left and right of The majority of the weight of the the mounting location by tapping the installed ventilation system will be wall or using a stud finder. supported by the lower retaining ^ Mark a vertical cutting line along the plate.
  • Page 30: Installation

    Installation...
  • Page 31 Installation 3 protective shields to prevent scratches to the chimney during installation. 8 large headed screws 5 x 40 mm 1 vent collar for securing the retaining plates and the for use with 6" (150 mm) exhaust canopy. ducting (S8 wall anchors included in the 1 reducing collar for use with 5"...
  • Page 32: Installation

    Installation Protective film Dismantling The casing is covered with a protective If the hood needs to be disassembled, film to prevent scratching during follow the instructions on the transport. "Installation diagram" in the reverse order. ^ Peel off the film before installing the casing parts.
  • Page 33: Air Extraction

    Air extraction Exhaust ducting and connections WARNING Use smooth or flexible pipwork made from approved non-flammable Danger of toxic fumes. materials for exhaust ducting. Gas cooking appliances release To achieve the most efficient air extraction and quietest noise levels, carbon monoxide that can be consider the following: harmful or fatal if inhaled.
  • Page 34: Condensate Trap

    Air extraction Condensate trap optional accessory – If the exhaust is ducted into an inactive flue, the air must be expelled In some cases, a condensate trap may parallel to the flow direction of the also be required to collect and flue.
  • Page 35: Electrical Connection

    If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or contact Miele’s Technical Service Department. ,WARNING: THIS APPLIANCE MUST BE GROUNDED...
  • Page 36: Technical Data

    Technical data Maximum load DA 5381 W / DA 5391 W ..430 W DA 5321 W ....450 W Overhead lighting DA 5381 W / DA 5391 W .
  • Page 40 Alteration rights reserved / 1711 M.-Nr. 07 901 910 / 01 INFORMATION IS SUBJECT TO CHANGE. PLEASE REFER TO OUR WEBSITE TO OBTAIN THE MOST CURRENT PRODUCT SPECIFICATIONS, TECHNICAL & WARRANTY INFORMATION.

This manual is also suitable for:

Da 5381 wDa 5391 w

Table of Contents