METRObility Optical Systems R111-12 Installation & User Manual

10mbps single interface line cards

Advertisement

Quick Links

S
INGLE
10BASE
PWR
TP
LK
AT
BNC
COL
Installation & User Guide
Models: R111-12 / R111-13 / R111-15 /
R
ADIANCE
10M
I
NTERFACE
10BASE
PWR
TP
LK
AT
FL
R
X
LK
M
M
AT
T
X
R111-16 / R111-18 / R111-1T
BPS
L
INE
10BASE
PWR
TP
LK
AT
FL
R
LK
X
M
M
AT
T
X
C
ARDS
10BASE
PWR
TP
LK
AT
FL
R
X
LK
S
M
AT
T
X
10BASE
PWR
TP
LK
AT
FL
R
LK
X
M
M
AT
T
X

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R111-12 and is the answer not in the manual?

Questions and answers

Summary of Contents for METRObility Optical Systems R111-12

  • Page 1 ADIANCE INGLE NTERFACE ARDS 10BASE 10BASE 10BASE 10BASE 10BASE Installation & User Guide Models: R111-12 / R111-13 / R111-15 / R111-16 / R111-18 / R111-1T...
  • Page 2 Metrobility Optical Systems, Inc. © 2001-2002, 2004 Metrobility Optical Systems, Inc. All rights reserved. Printed in USA.
  • Page 3: Table Of Contents

    Warranty and Servicing ................ 15 Metrobility, Metrobility Optical Systems, NetBeacon, and “twister” are registered trademarks of Metrobility Optical Systems, Inc. The Metrobility Optical Systems logo is a trademark of Metrobility Optical Systems, Inc. All others are trademarks of their respective owners.
  • Page 4: Overview

    Overview The Radiance 10Mbps single interface line cards offer transparent integration of fiber optic connectivity or copper-to-coaxial integration in Ethernet networks. These innovative solutions provide full signal restoration— with low bit delay—ensuring accurate data transmission and guaranteeing maximum cable length support. All cards are compatible with any Ethernet device.
  • Page 5: Installation Guide

    Installation Guide Follow the simple steps outlined in this section to install and start using your Radiance 10Mbps single interface line card. NOTE: Electrostatic discharge precautions should be taken when handling any line card. Proper grounding is recommended (i.e., wear a wrist strap). Unpack the Line Card Your order has been provided with the safest possible packaging, but shipping damage does occasionally occur.
  • Page 6 R111-12 Only On the RJ-45 to BNC line card, a jumper is used to set either internal or external termination of the BNC port. See the diagram below to locate the jumper, labeled JP1. • Connect pins 1 and 2 to enable internal 50 termination. •...
  • Page 7: Step 3: Set The Mdi-Ii/Mdi-X Switch

    Set the MDI-II/MDI-X Switch (twisted-pair ports only) To eliminate the need for crossover cables, the Radiance line cards have an MDI-II to MDI-X slide switch for each twisted-pair port. This switch is positioned directly behind its associated RJ-45 connector and allows simple setup in either straight-through (default) or crossover configurations.
  • Page 8: Step 4: Install The Line Card

    Install the Line Card The Radiance 10Mbps single interface line card offers the ease of plug- and-play installation and is hot-swappable. The card must be firmly secured to the chassis before network connections are made. Follow the simple steps outlined below to install your line card. Slot for Management Card Card Guide 10/100...
  • Page 9 10/100 10/100 10/100 10/100 10/100 10 BASE 10/100 100 BASE 10/100 10/100 10/100 10 BASE 10/100 10/100 10/100 10/100 MGT-10 Twisted-Pair Interface Twisted-pair ports provide shielded RJ-45 connectors that support a maximum segment length of 100m. Use Category 3, 4 or 5 cables. Fiber Optic Interface When making network connections, make sure that the transmit (TX) port of the card connects to the receive (RX) port of the connected...
  • Page 10: User Guide

    User Guide This section contains information about the operating features of the Radiance 10Mbps single interface line cards. LED Indicators The Radiance 10Mbps single interface line cards provide several LEDs for the visible verification of unit status and proper functionality. These LEDs can help with troubleshooting and overall network diagnosis and management.
  • Page 11: Link Loss Carry Forward (Llcf)

    Link Loss Carry Forward (LLCF) The Radiance 10Mbps single interface line cards incorporate an LLCF function for troubleshooting a remote connection. When LLCF is enabled, the FL and TP ports do not transmit a link signal until they receive a link signal from the opposite port.
  • Page 12: Technical Specifications

    Technical Specifications Data Rate Data Rate ______________________ 10Mbps half duplex; 20Mbps full duplex Bit Delay __________________________________________________ < 5 bits Environmental Power ___________________________________ 5V @ 1.0 Amp, 5W average Operating Temperature ____________________________________ 0 to 50 C Storage Temperature ____________________________________ -30 to 70 C Operating Humidity _________________________ 5% to 95% non-condensing Weight _______________________________________________ 5 oz (0.14 kg) Network Connections...
  • Page 13 Multimode F/O Interface (R111-13, R111-15, R111-18) Connector __________________________________________ SC, ST or SMA Wavelength _________________________________________________ 820nm RX Input Sensitivity ______________________________ -32.5 dBm minimum Output Power ______________________ -21.8 dBm to -16.8 dBm (50/125 m) _______________________ -19 dBm to -14 dBm (62.5/125 m) Supported Link Length ___________________________ up to 2km full duplex Cable Type ________________________________ 50/125 or 62.5/125 m F/O Multimode Fiber Optic Interface—Long Haul Distance Support...
  • Page 14: Product Safety, Emc And Compliance Statements

    Product Safety, EMC and Compliance Statements This equipment complies with the following requirements: • UL • CSA • EN60950 (safety) • FCC Part 15, Class A • EN55022 Class A (emissions) • EN55024: 1998 (immunity) • IEC 825-1 Classification • Class 1 Laser Product •...
  • Page 15: Warranty And Servicing

    Warranty and Servicing Three-Year Warranty for Radiance 10Mbps Single Interface Line Cards Metrobility Optical Systems, Inc. warrants that every Radiance 10Mbps single interface line card will be free from defects in material and workmanship for a period of THREE YEARS from the date of Metrobility shipment. This warranty covers the original user only and is not transferable.
  • Page 16 Product Manuals The most recent version of this manual is available online at http://www.metrobility.com/support/manuals.htm Product Registration To register your product, go to http://www.metrobility.com/support/registration.asp 25 Manchester Street, Merrimack, NH 03054 USA tel: 1.603.880.1833 • fax: 1.603.594.2887 www.metrobility.com 5660-000010 G 8/04...

This manual is also suitable for:

R111-16R111-13R111-18R111-15R111-1t

Table of Contents