T IM IN G PARAMET ERS
t0
Cycle Time (min)
t1
Address vali d to DIOR-/D IOW - setup (min)
t2
D IOR-/DIOW- 16-bi t (min)
t2i
D IOR-/DIOW- recovery ti me (min)
t3
DIOW- data setup (min)
t4
DIOW- data hold (min)
t5
D IOR- data setup (min)
t6
DIOW- data hold (min)
t6Z
D IOR- data tri state (max)
t9
D IOR-/DIOW- to address vali d hold (min)
tRd
Read Data Vali d to IORDY acti ve (min)
tA
IORD Y Setup Ti me
tB
IORDY Pulse Width (max)
MODE 0
MODE 1
MODE 2
600 ns
383 ns
240 ns
70 ns
50 ns
165 ns
125 ns
60 ns
45 ns
30 ns
20 ns
50 ns
35 ns
5 ns
5 ns
30 ns
30 ns
20 ns
15 ns
0
0
35 ns
35 ns
1250 ns
1250 ns
1250 ns
Figure 5 - 2

PIO Data Transfer To/From Device

MODE 3
MODE 4
180 ns
120 ns
30 ns
30 ns
25 ns
100 ns
80 ns
70 ns
70 ns
25 ns
30 ns
30 ns
20 ns
15 ns
10 ns
10 ns
20 ns
20 ns
20 ns
5 ns
5 ns
5 ns
30 ns
30 ns
30 ns
10 ns
10 ns
10 ns
0
0
0
35 ns
35 ns
35 ns
1250 ns
1250 ns