4.2.14 Roll Assembly #1 & Pinch Roll
1. Remove the Duplex Unit.
2. Slide the end of the Plate Stopper off of the post on the Frame L/H.
See illustration (1).
3. Tilt back the Duplex Assembly Unit Vertical.
4. Remove the Chute Upper.
5. Remove the two screws that are securing the Chute to the Supports
Duplex R/H and L/H and remove the Chute (1).
6. Loosen the screw that secures the Rear Interlock Switch (PL11.1.8:
Bracket Sensor) to the Duplex Unit Horizontal II (PL11.2) (2).
7. Remove the E-rings from both ends of Roll Assembly #1.
8. Remove the bearing from the right end of the Roll Assembly #1.
9. Remove the gear and bearing from the left end of the Roll Assembly
#1.
10. Lift the shaft up and out of the Chute.
11. Slide the shaft to the right and out of the Chute.
12. Unhook and remove the two Springs that hold the Brackets Pinch to
the Chute.
13. Remove the two Brackets Pinch along with the Roll Pinch from the
Chute.
14. Remove the two Brackets Pinch from the ends of the Pinch Roll.
Rev. 0
Chapter 4
DISASSEMBLY AND ASSEMBLY
Figure 4-14. Roll Assembly #1/Pinch Roll Removal