Chain Master Link - Compact Power BOXER 999-823 Operator's Manual

Trencher
Table of Contents

Advertisement

Routine Service and Maintenance

Chain Master Link

If the trencher chain needs to be removed from the trencher, it can be broken at the Master
Link.
When the Master Link is removed, the chain could fall off the trencher frame. Keep your
hands and feet from underneath the chain to prevent injury.
To separate the Master Link:
1. Inspect the chain and locate the master link (Item 1,
able pivot pin and cotter pin instead of two bolts.
2. Support the trencher chain from underneath the trencher frame.
3. Remove the cotter pin (Item 2,
then remove the pivot pin.
4. Remove the spacer tube (Item 4,
5. Using an appropriate lifting device, remove the trencher chain from the trencher frame.
6. Replace the trencher chain and reassemble the master link by reversing Steps 1-5.
4-28
CAUTION
Figure
4–24) from the pivot pin (Item 3,
Figure
4–24) from the chain links (Item 5,
3
4
5
1
Figure 4–24 Master Link
Figure
4–24), which will have a remov-
Figure
2
4–24) and
Figure
4–24).
2461

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Compact Power BOXER 999-823

This manual is also suitable for:

Boxer 118