HIGH VOLTAGE CABLE
Be sure switch and igniter are good before checking the high voltage cable and the switch is in the gas mode.
Disconnect DC power at the terminal block. Disconnect high voltage cable from electrode. Reconnect DC power to
the terminal block. If sparking starts, cable is good. If no sparking, disconnect DC power at the terminal block and then
disconnect high voltage cable at the igniter. Reconnect DC power to the terminal block.
RELAY (RM261 0/RM2810 3-WAY
MODELS ONLY)
Verify the selector switch is on DC mode and the thermostat is NOT completing the
circuit. Verify voltage is present between terminals 85 and 30.
Check for voltage between terminals 85 and 87. If voltage is present, the relay is
defective.
Verify the selector switch is on DC mode and the thermostat is completing the circuit.
Verify voltage is present between terminals 85 and 86.
If voltage is present, between 85 and 86 terminals, then voltage should be present between
terminals 85 and 87.
11
+