PLACEMENT OF GLOWING EMBERS AND LAVA ROCK

Placement of the glowing embers (rock wool) is very individual
and light coverage of the areas indicated will provide your best
effects. We recommend separation of the rock wool by hand and
make your coverage as light and fluffy as possible.
Place just enough embers on the burner to obtain the glow and a
gold, yellow flame.
Do not place embers (rock wool) over large ports in rear portion
of burner.
Rock wool should not be placed in the area of the pilot assembly.
Placing Lava Rock in Front of Burner on Fireplace Floor
Spread lava rocks on fireplace floor in front of the burner pan.
The lava rocks are for decorative effect and are not required for
fireplace operation.
ATTENTION: DO NOT PLACE LAVA ROCKS ON
BURNER, LOGS OR ROCK WOOL. THE LAVA ROCKS
SHOULD ONLY BE PLACED ON THE FIREPLACE
FLOOR.

OPERATION INSTRUCTIONS/FLAME APPEARANCE

Flames from the pilot (right back side of the pan burner) as well
as the main flame should be visually checked as the log set is
installed.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames.
NOTE: all flames will be random by design, flame height will
go up and down.
Avoid any drafts that alter burner flame patterns. Do not allow
fans to blow directly into fireplace. Do not place a blower inside
the burner area of the firebox. Ceiling fans may create drafts that
alter flame patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various
components of this appliance are treated with certain oils, films
or bonding agents. These chemicals are not harmful, but may
produce annoying smoke and smells as they are burned off during
the initial operation of the appliance, possibly causing headaches
or eye or lung irritation. This is a normal and temporary
occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.
14015-1-0903
Figure 5
Manual - Figure 6
Millivolt - Figure 7
Page 9