Troubleshooting - White Mountain Hearth VSM-18-1 Installation Instructions And Owner's Manual

Vented slope glaze burner/vented decorative log set
Table of Contents

Advertisement

1. Match will not light pilot.
a. Main shut-off valve closed.
• Make sure that the shut-off valve located on the pipe
supplying gas to the fireplace is open.
b. Air in the gas line.
• Light a match, turn valve knob to "PILOT" position and
depress, keep match near pilot burner until it lights.
c. Valve knob in "OFF" position.
• Turn valve knob to "PILOT" position and depress,
keep match near pilot burner until it lights.
d. Pilot orifice plugged up, not allowing gas to flow.
• This repair requires tools and some degree of experi-
ence. Ask serviceman for assistance.
e. No gas supply to the fireplace.
• Check plumbing to see if gas fireplace has been hooked
up to the gas supply line.
• Propane tanks is empty.
2. Pilot will not stay lit after carefully following lighting
instructions for VSR—Models.
a. Defective pilot generator (thermopile), remote wall switch.
• Check pilot flame. Must impinge on thermopile. Clean
and or adjust pilot for maximum flame impingement on
thermopile.
• Be sure wire connections from thermopile at gas valve
terminals are tight and thermopile is fully inserted into
pilot bracket.
• One of the wall switch wires may be grounded. Re-
move wall switch wires from valve terminals if pilot
now stays lit, trace wall switch wiring for ground. May
be grounded to appliance or gas supply.
• Check thermopile with millivolt meter. Take reading at
thermopile terminals of gas valve. Should read 325
millivolts minimum while holding valve knob de-
pressed in pilot position and wall switch "Off." Replace
faulty thermopile if reading is below specified mini-
mum.
b. Defective automatic valve operator — Turn valve knob to
"On." Place wall switch to "On" millivolt meter should
read greater than 100 M.V. If the reading is okay and the
burner does not come on, replace the gas valve.
c. Defective thermopile.
• Check all connections and try.
• If still not operating, disconnect lead between thermo-
couple switch and valve operator. Then disconnect
lead to pilot magnet and connect to valve operator
terminal (TP, TH). If pilot remains lit fault lies with
thermocouple. Check that bulb is in proper location. If
still not working replace thermocouple (see drawing in
manual for additional information).
Page 14

TROUBLESHOOTING

SYMPTOMS-POSSIBLE CAUSES AND CORRECTIONS
3. Pilot burning, no gas to burner, valve knob "On," wall
switch "On."
a. Wall switch or wires defective.
• Check wall switch and wires for proper connections.
Jumper wire cross terminals at wall switch, if burner
comes on, replace defective wall switch. If okay, jumper
wires cross wall switch wires at valve, if burner comes
on, wires are faulty or connections are bad.
b. Thermopile may not be generating sufficient millivoltage.
• Replace.
c. Plugged burner orifice.
• Check burner orifice for debris and remove.
4. Pilot will not stay lit after carefully following lighting
instructions for VSM—Models.
a. Defective thermocouple.
• Check that pilot flame impinges on thermocouple.
Clean and/or adjust pilot for maximum flame impinge-
ment.
• Ensure that the thermocouple connection at the gas
valve is fully inserted and tight (hand tight plus 1/4
turn) faulty thermopile if reading is below specified
minimum.
• Disconnect the thermocouple from the valve, place one
millivolt meter lead wire on the tip of the thermocouple
and the other meter lead wire on the thermocouple
copper lead. Start the pilot and hold the valve knob in.
If the millivolt reading is less than 15 mv, replace the
thermocouple.
b. Defective valve.
• If thermocouple is producing more than 15 millivolts,
replace faulty valve.
5. Frequent pilot outage problem.
a. Pilot flame may be too low or blowing (high) causing the
pilot to drop out.
• Clean and/or adjust flame for maximum flame im-
pingement on thermopile or thermocouple.
6. Main burner flame is too low or too high.
a. Check inlet supply pressure for "M" and "R" models.
b. Check manifold pressure on gas valve for "R" models and
inlet regulator on "M" models.