WIRING DIAGRAMS (cont.)
Thermostat
O/B
Heat Stage 2
(NA)
Heat Stage 1
W
Cool Stage 1
Y1
Cool Stage 2
Y/Y2
Fan
G
*
24VAC Hot Heating
Rh
24VAC Hot Cooling
Rc
24VAC Common
C
* Remove jumper when using split power (Indoor and Outdoor units
utilize separate transformers).
Fig. 8 - - Variable Speed, Step Modulating, Multi- - Stage and Single- - Stage
Furnace with 2- - Stage Air Conditioner
Furnace
Air Conditioner
W2
W/W1
Y1
Y/Y2
G
R
DHUM
COM
28
Y1
Y/Y2
R
C
A12240