10164-L Sampler Control
Cable for use with Isco and
Sigma Autosamplers
Revision: 9/12
C o p y r i g h t
©
1 9 9 8 - 2 0 1 2
C a m p b e l l
S c i e n t i f i c ,
I n c .

Advertisement

Table of Contents
loading

Summary of Contents for Campbell 10164-L

  • Page 1 10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers Revision: 9/12 C o p y r i g h t © 1 9 9 8 - 2 0 1 2 C a m p b e l l S c i e n t i f i c , I n c .
  • Page 3 Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless otherwise specified in the corresponding Campbell pricelist or product manual.
  • Page 4 (435) 227-9106. Campbell Scientific is unable to process any returns until we receive this form. If the form is not received within three days of product receipt or is incomplete, the product will be returned to the customer at the customer's expense.
  • Page 5: Table Of Contents

    Table of Contents PDF viewers: These page numbers refer to the printed version of this document. Use the PDF reader bookmarks tab for links to specific sections. 1. General ................1 2. Specifications .............1 Cable Length Considerations ...............1 3. Wiring................2 General Wiring Information..............2 Triggering Sampler ................3 Sense Sampler Event Markers..............3 Inhibit Sampler’s Program ..............3...
  • Page 6 Table of Contents...
  • Page 7: General

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers General The 10164-L sampler control cable enables a datalogger to trigger an Isco, American Sigma, or connector-compatible autosampler. Through this cable, the datalogger can inhibit the sampler from running its programmed sampling routine and sense and record when the sampler indicates that it has taken a sample.
  • Page 8: Wiring

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers Wiring General Wiring Information FIGURE 3-1 shows a schematic of the 10164 and TABLE 3-1 shows pin connector and wire functions. Sections 3.2 through 3.4 provide information about connecting the wires to a datalogger.
  • Page 9: Triggering Sampler

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers Triggering Sampler TABLE 3-2 shows the datalogger connections required to trigger the sampler. TABLE 3-2. Datalogger Wiring for Triggering Sampler CR800 CR500 CR850 CR510 CR1000 CR10(X) Color Description CR3000 CR23X Purple Ground...
  • Page 10: Programming

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers TABLE 3-4. Datalogger Wiring to Inhibit a Sigma Sampler Program CR800 CR500 CR850 CR510 CR1000 CR10(X) Color Description CR3000 CR23X Purple Ground Brown Control Port Control Port Control Port Control (C1, C2,…) (C1, C2,…)
  • Page 11: Crbasic Programming

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers CRBasic Programming 4.1.1 Trigger Sampler To trigger the sampler, the datalogger program must set the port high, delay for at least 0.5 seconds, and then set the port low. TABLE 4-1.
  • Page 12: Inhibit Sampler's Program

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers 'CR1000 Series Datalogger 'Declare Public Variables Public Events 'Define Data Tables DataTable (Sampler,1,1000) Totalize (1,Events,FP2,False) EndTable 'Main Program BeginProg Scan (1,Sec,0,0) PulseCount (Events,1,1,0,0,1.0,0) 'Call Output Tables CallTable Sampler NextScan EndProg 4.1.3 Inhibit Sampler’s Program To inhibit a sampler’s onboard program, use the PortSet() instruction.
  • Page 13: Edlog Programming

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers TABLE 4-4. Wiring for Example of Inhibiting a Sigma Sampler Onboard Program Color Description CR800, CR850, CR1000, orCR3000 purple Ground brown Control Port clear Shield For samplers such as the products manufactured by Sigma, the onboard program is inhibited by setting the control port high.
  • Page 14: Sense Sampler Event Markers

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers Do (P86) 1: 52 Set Port 2 Low You can also supply the trigger signal from switched excitation if no control ports are available. In this case, connect the yellow cable to the desired excitation channel (say E3) and pulse the channel using Instruction 22 as follows: Excitation with Delay (P22)
  • Page 15: Inhibit Sampler's Program

    10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers CR10(X) Program (Subroutine 98 in Program Table 3) Table 3 Subroutines 1: Beginning of Subroutine (P85) 1: 98 Subroutine Number 2: Z=Z+1 (P32) 1: 10 Z Loc [ Sample_No ] 3: Do (P86) 1: 10 Set high Flag 0 (output flag)
  • Page 16 10164-L Sampler Control Cable for use with Isco and Sigma Autosamplers...
  • Page 18 Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbellsci.com Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za • cleroux@csafrica.co.za Campbell Scientific Australia Pty. Ltd. (CSA)