Temperature Programs - Lux Products TX500U Installation And Operating Instructions Manual

Smart temp universal 5/2-day programmable thermostat
Table of Contents

Advertisement

TEMPERATURE PROGRAMS:

By default, this thermostat has 4 separate program periods for both Heat and
Cool mode, they are: MORN, DAY, EVE, and NITE. Each period ends at the
start time of the following period. The heat programs are set in HEAT mode,
and the cool programs are set in COOL mode.
NOTE: If the thermostat is configured to use only 2 periods per day instead
of 4 (HARDWARE SETUP OPTIONS), the thermostat will only use the DAY
and NITE periods. The MORN and EVE periods will not be visible on the
screen.
SET TEMPERATURE PROGRAMS: Move the Set Slide switch to the TEMP
PROG position. Programming will start with all 5 weekdays, Monday
through Friday (all grouped together). Use the UP/DOWN buttons to adjust
the start time for the MORN period, then press the NEXT button to advance.
Use the UP/DOWN buttons to adjust the set temperature for the MORN
period, then press the NEXT button to advance. Now adjust the start time
and set temperature for the DAY period, pressing the NEXT button after each
to advance. Continue with these same steps to adjust the start times and set
temperatures for the EVE and NITE program periods.
When the NITE period is finished for the weekdays, the thermostat will
advance forward to the weekend program, with the MORN period start time
flashing. You will be setting the program periods for both Saturday and
Sunday (grouped together). Perform the same steps that you used for
setting the weekday periods, pressing the NEXT button to advance through
each flashing value. Return the Set Slide switch to the RUN position when
you are finished.