Installer Confi Guration Menu - Emerson 1F86ST-0471 Instructions Manual

Blue selecto thermostat with automatic heat/cool changeover option
Table of Contents

Advertisement

INSTALLER/CONFIGURATION MENU
With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display will
show item #1 in the table below. Press Menu to advance to the next menu item. Press
Shaded items are not available on 1F86.
MENU
PRESS
REF
HP
SS
BUTTON
1
1
MENU
2
2
1
MENU
3
3
2
MENU
MENU
4
4
3
MENU
5
4
MENU
6
5
MENU
7
5
MENU
8
6
6
MENU
9
7
7
MENU
10
8
8
MENU
11
9
9
MENU
12
10 10
MENU
13
11 11
MENU
MENU
14
12 12
Arrancar
1. Select Reversing Valve Output (SS/HP switch must
be set at HP, omitted if SS/HP switch is SS Position)
– The O/B option is factory set at "O" position. This will
accommodate the majority of heat pump applications,
which require the changeover relay to be energized in
FRIO. If the thermostat you are replacing or the heat pump
being installed with this thermostat requires a "B" terminal,
to energize the changeover relay in CALOR, the O/B
option should be set at "B" position.
2. Program Options 1F80 only – This control can be
confi gured for 5/2 day or 5/1/1 day programming or non-
programming mode. The default setting is P2, indicating
5/2 day programming. The programs per week can be
toggled to P3 or P0 by pressing the
selection of 0 Days for non-programmable will eliminate
the need for EMR, and that step in the menu will be
skipped.
3. Select Frio Ahorro (Cool Savings™) and value
– Selects the Frio Ahorro feature On or OFF. If selected
On, press MENU to select the amount of adjustment
for the feature in Frio mode with 1 (1°) being the least
amount of adjustment and 6 (6°) being the most amount
4
INSTALLER/CONFIGURATION MENU
Press
DISPLAYED
select from listed options
(FACTORY DEFAULT)
On (Frio O)
P (2)
Frio Ahorra CE
Frio Ahorra CE On
(OFF)
Frio Ahorra (3)
E (On)
CR Calor
(ME)
CR Frio
(AL)
CR Bomba de Calor
(AL)
Cd (OFF)
Auto Calor
Calor Frio Off,
Frio Off
Calor Off with Vent icon,
Calor Off without Vent
L (On)
0
1 AL, 2 AL, 3 AL, 4
1 bA, 2 bA, 3 bA, 4 bA
F
Cambiar Filtro (OFF)
Cambiar Filtro On
Cambiar Filtro 200 h
25 h to 1975 h in
25-hour increment
or
keys. A
or
to
Calor b On
Reversing Valve Output (SS/HP switch must
P 3, P 0
(For programmable thermostat only)
Select Frio Ahorra (Cool Savings) on or off
6, 5, 4, 2, 1
Selects Frio Ahorra value 1 (low) to 6 (high)
E OFF
Selects Energy Management Recovery (EMR)
AL, bA
Adjustable Anticipation (Calor) (only when
SS/HP switch is at the SS position)
bA
Adjustable Anticipation (Frio) (only when
SS/HP switch is at the SS position)
bA
Adjustable Anticipation (Bomba de Calor)
(only when SS/HP switch is at the HP position)
Cd On
icon, Frio Off,
Auto Off
L OFF
Adjustable Ambient Temperature Display
AL,
C
Selects Fahrenheit/Celsius Temperature
Selects Filter Change-out Indicator
When on, selects time in 25 hour increments
of adjustment. Default value is 3 (3°). In normal operation
"Ahorro" will appear under "Vent"
Cool Savings is an optional energy saving feature that
can reduce your cooling costs. It is based on the principal
that lower indoor humidity makes a slightly higher
temperature feel more comfortable. Frio Ahorro operates
during periods of high demand which normally occur
on the hottest summer days when the cooling system
may run for hours to reach the thermostat setting. Long
cooling run times also lower the indoor humidity. Frio
Ahorro very slowly adjusts the setpoint temperature to
make the setpoint closer to the displayed temperature, to
a maximum number of degrees selected. Adjusting the
setpoint temperature over a long cooling run time allows
the system to reach your set temperature and turn off.
The room temperature will actually be higher than the
thermostat displays, but the reduction in humidity will allow
comfort at the slightly higher temperature. When Frio
Ahorro is making adjustments, "Save" will show next to
the setpoint temperature and the room temperature may
vary within the adjustment range selected.
If this feature is selected OFF, no change will occur when
the cooling system is continually running during periods of
high demand.
or
to change an item option.
COMMENTS
be in the Heat Pump HP position)
Selectable Programs Per Week
on or off
Compressor Lockout Time
System Mode Confi guration
with Automatic Changeover
Selects Display Light on or off
Display
Returns to Normal Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1f80st-0471

Table of Contents