(such as RF pulse signal) can be develop. Prior to third part testing. A near-field Mainly Performance and Calibration observed from ATTEN spectrum analyzer sniffer probe set, AZ530, can be used to locate clearly, where figures are expanded by...
Specifications Input/output The H-Field Near-Field probe Probe are all matched to the 50 inputs of Spectrum analyzers or RF-receivers. The Frequency range: 0.15~1050MHz Signal input: N connector The H-Field probe provides a voltage to the power can be supplied either from batteries, 10ppm/year Impedance: 50 Stability:...
RF Signal Generator for mobile phones has are all above several ten thousands RMB, it is analyzer. been researched by ATTEN, its frequency as not affordable for most radio fans, service men well as the output amplitude can be When connect mobile phone to RF signal and even medium or small sized enterprises.
Spectrum Analyzer (C). For the D position has been subject to severe transport stress factory in a safe condition. This instruction and care. ATTEN shall not be obliged to (10 inclination), the handle should be turned (e. g. in poor packaging).
The spectrum analyzer works according to the Switching over the mains / line voltage Safety including the instructions prior to fuseholder is not permissible; ATTEN assumes triple superhet receiver principle. The signal to operating the AT6010/AT6011. No special no liability whatsoever for any damage caused be measured (fin = 0.15MHz to 1050MHz) is...
Due to the frequency conversion principle,a steps. As previously pointed out, the on the screen. It enables small level spectral (20) Output Info (AT6011 only) spectral line is visible at 0Hz. It is called maximum permissible input voltages may not lines to become visible which normally would FREQENCY: 1 to 1050MHz If-feedthrough.
Introduction to the operation of the input attenuators (14) can contains information not found in the time signals in the frequency range of the analyzer. be tested at a level of -27dBm. The spec-tral domain and therefore, the spectrum analyzer hence the name real-time.
displayed. and displayed. When the frequency narrowest bandwidth that can be used to Frequency Measurements Resolution difference between the input signal and the LO distinguish a single input signal is 10kHz. Any frequency is equal to the IF frequency, then narrower IF-filter will result in more than one Before the frequency of a signal can be The frequency scale can be scanned in three...
of two analyzers, to compare sensitivity by 3dB) because the signal power=average Dynamic range requires several things then. voltage from the LO is too large compared to specifications for equal bandwidths. A noise power. The display range must be adequate, no the input signal voltage then the conversion spectrum analyzer sweeps over a wide spurious or unidentified response can occur,...
Mainly Performance configuration is use for making selective and measurement set-up, they are completely Gratitude. Sensitive precise measurement of frequency, eliminated from the CRT display. 6. Frequency Response and Calibration of by tuning to the signal and switching to zero It means signal response of spectrum analyzer scan.
Need help?
Do you have a question about the AT6010 and is the answer not in the manual?
Questions and answers