Hard-wired ac powered moments lavatory proximity faucet (9 pages)
Summary of Contents for Selectronic 7055.105
Page 1
M 9 6 5 2 5 5 R E V. 1. 6 NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: faucetsupport@americanstandard.com...
Page 2
NOTE TO INSTALLER: Please give this manual to the customer after installation. NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S.
Roughing-in Dimensions Fig. 1 191mm (7-1/2) FINISHED WALL OR BACKSPLASH MIN. 1" CLEARANCE 191mm (7-1/2) 165mm 140mm (6-1/2) (5-1/2) MOUNTING SURFACE 66mm ( 2-5/8) 38mm 32mm (1-1/4) (1-1/2 ) GENERAL DESCRIPTION: Electronic faucet with proximity operation. Vandal resistant solid brass construction single post mounting. 457mm (18) Operates on DC (battery) or AC power.
No. M968808 M968808 NOTE TO INSTALLER: Please give this manual to the customer after installation. To learn more about American Standard Faucets visit our website at: www.us.amstd.com or U.S. customer's e-mail us at: faucetsupport@amstd.com For Parts, Service, Warranty or other Assistance,...
Page 5
HOW TO CHANGE SENSOR Fig. 2 RANGE; (Factory set at 6") Fig. 2 1. Setting the Detection Zone (Distance): Remove the FAUCET COVER (1) by unthreading the REMOVE LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW REPLACE (4) at the back of the FAUCET.
Page 6
HOW TO INSTALL AND CHANGE Fig. 5 BATTERY; Fig. 5 1. Remove the FAUCET COVER (1) by unthreading the LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW (4) at the back of the FAUCET. Pull FAUCET COVER (1) up and off.
Page 7
HOW TO CLEAN FILTER SCREEN Fig. 9 ON SOLENOID VALVE; Fig. 9 & 10 1. Remove the FAUCET COVER (1) by unthreading the LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW DISCONNECT (4) at the back of the FAUCET. Pull FAUCET COVER WIRE CONNECTION (1) up and off.
Page 8
CHANGE HOT LIMIT SETTING FROM 95% TO 85%; Fig. 13 1. Remove the FAUCET COVER (1) by unthreading the LEVER SCREW (2) and pulling off the LEVER HANDLE (3). Unthread the FAUCET COVER SCREW (4) at the back of the FAUCET. Pull FAUCET COVER (1) up and off.