We provide a simple command-line utility, called PPIC, to read and configure the power control logic
in the SL6500 Scalable System. Versions are available for Microsoft
2008 and for the Linux
®
from the command line without any command-line options will provide the options shown below.
HP ProLiant Power Interface Control Utility v.1.09
Copyright (c) 2003, 2009 Hewlett-Packard Development Company, L.P.
Usage: POW [Options]
options:
-d
Display and Log Power Status and Configuration
-s
Set Power Configuration Mode
Disabled)
Performance w/
License
-c
Calibrate and Display Power Limits
-p
Poll and Log Power Readings
-o<name> override output log filename
Power control logic in the z6000 G6 chassis operates in one of four possible modes (Table 2).
operating system after installing the OS IPMI driver. Running the PPIC utility
-v
verbose data displayed
-m<mode>
00= No Redundancy Mode (Power Throttling
01= AC Redundancy with Throttling Mode (Max
Redundancy)
02= Full AC/DC Redundancy Mode
03= User Configurable Mode (LO100 Advanced
Required)
-l<power limit> (in Watts - Required for <Mode 03)
-v
verbose data logged
-f<frequency> (in secs)
-t<duration of run> (in secs)
(default log filename= ppic.log)