Airstream 1100 SERIES Operation And Service Manual page 10

1100 series single fan portable dryer
Table of Contents

Advertisement

LOW SPEED METERING
ROLL POTENTIOMETER (10)
This is used to adjust the LOW
speed of the metering roll when the
2 SPEED and MOISTURE CON-
TROL THERMOSTAT are in use.
HIGH SPEED METERING
ROLL POTENTIOMETER (11)
This is used to:
• Set the HIGH speed of the meter-
ing roll when the 2 SPEED auto-
matic moisture control feature of
the dryer is utilized.
• Set the speed of the metering
rolls when the 1 SPEED auto-
10
DRYER CONTROL PANEL
matic moisture control feature of
the dryer is utilized.
• Set the speed of the metering
rolls during continuous flow op-
eration when the moisture control
is not used.
• Set the rate of grain discharge from
the dryer during the unload cycle of
staged batch dryer operation.
DRYER POWER
START SWITCH (12)
This switch starts and operates the
dryer based on switch settings. If
other switch settings are in the OFF
position, individual dryer compo-
The Airstream Dryer Control Panel.
nents can be operated by turning the
DRYING MODE switch to CON-
TINUOUS FLOW, pressing the
DRYER POWER START button and
then turning ON the desired dryer
component.
DRYER POWER
STOP SWITCH (13)
This switch stops all dryer func-
tions. If an automatic dryer shut-
down occurs, first determine and
correct the cause of the shutdown.
Then, press the DRYER POWER
STOP button to reset the dryer be-
fore restarting.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pneg-339

Table of Contents