Kb-dar modified for motion detector interface

Advertisement

Quick Links

The KB-DAR-M allows any standard motion detector or activation device with a normally open contact to
be interfaced with the KB-3MRD Video System. When the motion detector is tripped, the camera will turn
on and a chime will be heard at the inside monitor station(s), indicating that there is some activity near
the door station location.

WIRING DIAGRAM:

Motion Detector*
Motion Detectors with N/O Contacts:
Detection Systems DS720I
Pulnix 6612
Intellisense 8140S
Ademco 1998PI
Sentrol AP750
Installation Guidelines:
1. The motion detector must provide a normally open momentary contact. A Photelectric beam, pressure
pad, or remote call button can also be used to activate the video door station.
2. The KB-DAR-M works with the KB system only. Standard KB-DAR's can be used in the same system if they
are not interfaced with a remote activation device.
Note:
Only information concerning the use of the KB-DAR-M is shown here.
For complete system installation, please refer to the instruction manuals included with the video system.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
KB-DAR Modified for Motion Detector Interface
- INSTRUCTIONS -
* Or any signaling
device that provides a
normally open
momentary dry closure.
KB-DAR-M
A1
A2
White
KB-DAR
White
A1
A2
Door Strike
Toll Free Technical Support:
Aiphone 871802 wire
Aiphone 871802 wire
PT-1210N
(AC Transformer)
+
-
PS-2420UL
1-800-692-0200
E-mail tech@aiphone.com
KB-3MRD
1A1
1A2
2A1
2A2
KB-3HRD
B1
1A1
871802
B2
1A2
Yel
Org
+
-
+
-
KB-DAR-M Instr.