Download Print this page

GE AP950PI - Security High-Security PIR Motion Sensor Installation Instructions page 2

Pir detector

Advertisement

Mounting and Wiring the Detector
1.
Separate the front housing from the back housing by pressing in
on the opening tab at the bottom of the unit with a small, flat-
bladed screwdriver. See Figure 3.
2.
Select and remove the appropriate corner or flat wall mounting
knockouts and the cable entry knockout on the back housing.
See Figure 1.
3.
Strip the cable 2 inches (5cm) and pull it through the cable entry
knockout. Use screws and wall anchors, if necessary, to attach
the back housing to the wall. Do not overtighten.
4.
Select the appropriate coverage pattern. See Selecting the
Coverage Pattern.
Opening tab
Figure 3. Front housing interior
5.
Set the sensitivity, mode, and LED jumpers for the application
desired. See Setting the Sensitivity, Mode, and LED.
6.
Strip 1/4 inch (0.6cm) of insulation from each wire.
7.
Insert each wire into the appropriate terminal and tighten
screws. Push the wires into the strain relief. See Figure 3.
8.
To close the unit, insert the hinge tabs at the top of the front
housing into the slots at the top of the back housing then swivel
the front housing toward the back housing to snap the unit
closed. See Figure 1.
9.
Fasten the housings together with the screw provided.
Selecting the Coverage Pattern
The coverage pattern for the unit can be modified to fit specific
applications by masking off mirror curtains. Curtains should be
masked to avoid sources of false alarms, such as heaters, air
conditioners, and windows.
Remove the mirror by inserting a small screwdriver between the mirror
and the side of the front housing and gently prying the mirror out. Do
not pry from the end of the housing because the mirror may be
scratched. See Figure 3.
2
If necessary, use one or more of the following methods to modify the
coverage pattern:
Use one or both of the plastic masks provided to mask off large
areas of coverage as shown in Figure 4.
Mask the appropriate mirror curtains with the adhesive labels
provided. See the example shown in Figure 5. Do not use sharp
objects to remove unwanted labels. If necessary, carefully peel
the label off.
Use the cardboard undercrawl window mask as shown in Figure
6. The undercrawl mask allows objects to be placed within 5 feet
(1.5m) of, or directly below, the unit.
After selecting the coverage pattern, snap the mirror back into the
front housing by pushing the mirror down into the mirror snaps (see
Cable strain relief
Figure 3). Then rotate the mirror down toward the front housing until
it snaps into position.
Wires
Terminal block
GND +12V NC COM
Jumpers:
SENS MODE
LED
Mirror snaps
Mirror
1
Figure 4. Plastic masks
A
1
2
3 4 5 6
7
1
2
3
4
5
6
B
A
B
Figure 5. Adhesive labels
7.9 ft
(2.4m)
5.0 ft
(1.5m)
Figure 6. Cardboard undercrawl window mask
1
2
2
8
9
7 8
9
AP950PI PIR Detector
AP950PI PIR Detector
AP950PI PIR Detector
AP950PI PIR Detector
AP950PI PIR Detector

Advertisement

loading