TECHNICAL DATA

DIMENSIONS
Height to hotplate
Space for fixing at hotplate level
Space for fixing above hotplate level
Minimum space above hotplate
Weight of appliance
Minimum distance from rear wall
CONNECTIONS
Gas
Electric
IGNITION
Spark generator
GRILL
Heat Input
Injector Marking
HOTPLATE
Heat Input
Injector Marking
Heat Input
Injector Marking
O V A T I O N 6 0 T & C
Height
900mm (nominal)
2mm minimum clearance
Flush-see important note 'Location of Appliance' page 43.
787mm (If a cooker hood is fitted refer to the cooker hood
installation instructions).
64.5kg.
5mm (spacer given by pressed spacer on vent panel).
Rear left hand side of cooker at hotplate level.
Rc½ (½" B.S.P. female).
220V/240V 50 Hz mains 3 core cable is supplied with an integral,
moulded plug fitted with a 3 amp fuse.
APCO 6+1 MG 7424/1
Natural Gas
3.3kW (11263 Btu/h)
138
R.H.F.
1.0kW
(3412 Btu/h)
(6824 Btu/h)
079
R.H.F.
1.0kW
(71.85 g/h)
(143.7 g/h)
051
41
Width
600mm (nominal)
L.P.Gas
3.0kW (215 g/h)
088
Natural Gas
R.H.R.
L.H.R.
2.0kW
2.0kW
(6824 Btu/h)
104
104
L.P.Gas
R.H.R.
L.H.R.
2.0kW
2.0kW
(143.7 g/h)
072
072
Depth
600mm
(to front of
door panel)
L.H.F
2.8kW
(9554 Btu/h)
130
L.H.F.
2.7kW
(194 g/h)
083