Hp Embedded Sata Raid; Server Deployment; Hp Proliant Easy Set-Up Cd - HP DL165 - ProLiant - G6 Introduction Manual

Technologies for hp proliant 100-series g5 (generation 5) servers, 2nd edition
Hide thumbs Also See for DL165 - ProLiant - G6:
Table of Contents

Advertisement

1+0, and 5. The controller supports mirror splitting for RAID 1 arrays. This functionality allows the
user to split a RAID 1 mirror into two separate RAID 0 arrays
. The controller also supports mirror
7
recombining, which is combining two RAID 0 arrays into a RAID 1 mirror. The battery-backed write
cache is not required for this feature. RAID 6 (double parity) is available when using the BBWC.
8
Some server configurations include a BBWC on the P400 controller. The BBWC is also available as
an option.
The BBWC is required for capacity expansion, which allows the user to add a physical disk to an
existing array. The controller then recalculates parity and balances the data across the disks. During
the expansion, data and logical structures on the array are preserved.
The P400 controller supports a recovery ROM and Online Drive Flashing. In the event of a failed
attempt to flash the controller's ROM, the recovery ROM reverts to the previous good ROM. With
Online Drive Flashing, disk drive firmware updates can be pre-loaded onto the controller and the
controller will flash the firmware onto the disk drives at the next reboot.

HP Embedded SATA RAID

The HP embedded SATA RAID that comes standard on most ProLiant 100-series servers offers basic
data protection. The RAID is implemented through the option ROM and device driver. Unlike OS
RAID, SATA RAID allows booting from a degraded RAID 1 array (that is, a failed drive) without
manual intervention. With OS RAID, a rescue floppy/CD or re-ordering of drives is required under
certain failure scenarios. Although OS RAID is implemented through the operating system, SATA RAID
is independent of the operating system.
In the hardware RAID model, RAID operations are performed by a dedicated controller with
dedicated memory and processor. Hardware RAID is achieved through controllers such as HP Smart
Array controllers. HP Embedded SATA RAID supports RAID 0, 1 and 10, and a maximum of four non-
hot plug SATA drives. RAID 5 is available on the ProLiant ML115 G5 server. HP Embedded SATA
RAID supports Microsoft® Windows®, Linux® and NetWare operating systems.

Server deployment

Deployment is a crucial step in setting up a server. HP has developed deployment utilities that are
tailored to a specific environment.

HP ProLiant Easy Set-up CD

The ProLiant ML110 G5 and ML115 G5 servers include an Easy Set-up CD that allows quick, single-
server deployment suited for small and mid-sized businesses. The CD includes tools and utilities that
simplify server installation tasks such as these:
• Preparing the server for a specific operating system (OS)
• Loading applicable licenses and documentation
• Configuring the array controllers and storage devices
• Performing diagnostics
7
For more information on splitting or "breaking" a mirror, refer to the white paper "RAID 1(+0): breaking mirrors and
rebuilding drives HOWTO," available at
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00378986/c00378986.pdf.
8
For detailed information about RAID 6, refer to the HP technology brief titled "RAID 6 with HP Advanced Data Guarding
technology: a cost-effective, fault-tolerant solution" available at
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00386950/c00386950.pdf.
9