Gas Piping - Allied Air 80G1UH Installation Instructions Manual

Warm air gas furnace upflow / horizontal left and right air discharge
Table of Contents

Advertisement

Gas Piping

CAUTION
If a flexible gas connector is required or allowed by the
authority that has jurisdiction, black iron pipe shall be
installed at the gas valve and extend outside the furnace
cabinet. The flexible connector can then be added
between the black iron pipe and the gas supply line.
Gas Supply
1. This unit is shipped standard for left or right side
installation of gas piping (or top entry in horizontal
applica-tions). Connect the gas supply to the piping
assembly.
2. When connecting the gas supply piping, consider factors
such as length of run, number of fittings, and furnace
rating to avoid excessive pressure drop. Table 9 lists
recommended pipe sizes for typical applications.
3. The gas piping must not run in or through air ducts,
clothes chutes, gas vents or chimneys, dumb waiters,
or elevator shafts.
Note: Capacity given in cubic feet (m³) of gas per hour and based on 06.0 specific gravity gas.
506526-01
4. The piping should be sloped 1/4 inch (6.4 mm) per 15
5. A 1/8" N.P.T. plugged tap or pressure post is located on
6. In some localities, codes may require the installation of
Compounds used on threaded joints of gas piping must
be resistant to the actions of liquified petroleum gases.
NOTE: If emergency shutoff is necessary, shut off the main
manual gas valve and disconnect main power to the furnace.
The installer should properly label these devices.
Gas Pipe Capacity - ft³/hr (m³/hr)
Table 9
Issue 1031
feet (4.57 m) upward toward the meter from the furnace.
The piping must be supported at proper intervals [every
8 to 10 feet (2.44 to 3.01 m)] with suitable hangers or
straps. Install a drip leg in vertical pipe runs to the unit.
the gas valve to facilitate test gauge connection. See
Figure 35.
a manual main shut off valve and union (furnished by
the installer) external to the unit. The union must be of
the ground joint type.
IMPORTANT