Dell PowerEdge C5220 Using Instructions page 14

Using the baseboard management controller
Hide thumbs Also See for PowerEdge C5220:
Table of Contents

Advertisement

Table 1-4. LED Status
LED
Color
ID LED
Blue
Heartbeat
Green Off
LED
Table 1-5. Blinking Fault LED Conditions
Index
Sensor Name
CPU Temp
1
Ambient Temp,
DIMM Temp
Rear Temp 1
Rear Temp 2
Rear Temp 3
SLED 12V
2
14
Status
Occurrence
Off
Normal status (by IPMI
Chassis Identify
command or System ID
Button)
Solid On Identify the system
Blinking Identify the system with
interval
BMC is not ready
Blinking BMC is ready
Event Triggers
• Upper Critical Going High
• Upper Non-Critical Going High
• Upper Critical Going High
• Upper Non-Critical Going High
Note
Turn off the ID LED.
1. ipmitool raw 0x00 0x04
0x00
2. ipmitool raw 0x00 0x04
0x00 0x00
Turn on the ID LED.
1.ipmitool raw 0x00 0x04 0x3c
01
1. IPMI chassis identify
command without request
data ipmitool raw 0x00 0x04
2. IPMI chassis identify
command with only 1
parameter data ipmitool raw
0x00 0x04 0x3c (blink 60 sec)
3. IPMI chassis identify
command with 2 parameter
data ipmitool raw 0x00 0x04
0x3c 0x00 (blink 60 sec)

Advertisement

Table of Contents
loading

Table of Contents