Sanyo PLC XU115 - XGA LCD Projector Owner's Manual page 23

For windows
Hide thumbs Also See for PLC XU115 - XGA LCD Projector:
Table of Contents

Advertisement

Description of warning value
Warning Column
Connect
Power status
Input signal status
Inside Temperature status (A to
C]
External Temperature status
Lamp status
Lamp time
Filter status
Filter time
Option Box filter status
Option Box filter time
(Auto play error)
(Mail error)
(System error)
0 The column order and width of the event log window are saved to the registry of the computer.
0 Up to 1000 of events can be stored. If it exceeds 1000 events, the oldest event is deleted and the
latest event is added. The event log can be saved to the management file.
Description of Event, Type, Warning column, Warning value
Warning Value
Un-connected
Connected *
Acquisition error
Power failure
TemperatureError
NormalAfterTempError
RS232CFailure
Power management
Shutter management
LampFailure
Normal(Standby) *
Normal(OnCoolingDown) *
SignalIsInterrupted
SignalIsInputted *
Abnormal
ON *
Failure
Replace
(lamp time)
Clogged
(filter time)
Clogged
Error
(filter time)
Error
n/a
0 The warning value with "*" in the above table shows the
event when the alert has cleared, alert type is "OFF".
Description
Projector has been disconnected from the network
Projector has been connected to the network
PJ Network Manager could not acquire the MIB information
from the equipment
Projector turned off due to the power failure of the projector
The projector turned off due to temperature error occurred
Normal after temperature error occurred
The RS-232C communication error occurred
The power management function turned projector lamp off
The shutter management function turned projector lamp off
The lamp failure occurred
Projector turned into standby normally
On cooling down normally due to projector turned off
The signal was interrupted
The signal was inputted again
The projector turned off when the temperature was
abnormally high
When the lamp is on
When the lamp failed to ignite.
It reached lamp replacing time.
It reached user setting lamp replacing time
Filter was clogged
It reached user setting filter time
Filter was clogged
The option box filter had an abnormality
It reached user setting option box filter time
The error occurred during the auto image display
PJ Network Manager could not send mail
PJ Network Manager could not acquire the memory
PJ NETWORK MANAGER
OWNER'S MANUAL
23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pj network manager

Table of Contents