• To attach the inner rails to the SAN Switch 2/32, use the screw
holes marked 32.
• To attach the inner rails to the 4/8, 4/16, 8/8, or 8/24 SAN
Switch, use the five screw holes marked 8. The plenum requires
one screw hole marked 8 and one screw hole marked 16, as
shown in
Figure 8
on page 6.
• To attach the inner rails to the 4/32, 4/32B, 4/64, 8/40, or
8/80 SAN Switch, or the 400 MP Router, use the screw holes
marked 16, as shown in
• To attach the inner rails to the MP Router, FCoE Converged
Network Switch, or Encryption SAN Switch, use two screw holes
marked R and one screw hole marked 16.
CAUTION:
Be sure to use the screw holes labeled 8 when attaching
the inner rails to the SAN Switch 2/16V or SAN Switch
2/16N.
Figure 7
on page 5.
7.
Secure the two inner rails (one on each side) to the device using
the appropriate number of screws. (See
For example,
Figure 6
with three screws, using two screw holes marked R and one screw
hole marked 16. Attaching both rails requires six screws.
Figure 7
shows an inner rail attached to the 4/64 SAN Switch with
five screws, using the screw holes marked 16. Attaching both rails
requires ten screws.
Figure 6 Securing the inner rails to the MP Router
Figure 7 Securing the inner rails to the 4/64 SAN Switch
NOTE:
For factory integration only , tighten the #8-32 x
5/16-inch Phillips panhead SEMS screws and torque
between 6 and 8 inch-pounds.