Figure 3-2
80 is the new trigger point.
Figure 3-3
1
: change behavior type
2
: change behavior interval
3
: change threshold boundary level
4
: change custom unit
5
: change custom timebase
6
: change custom low
7
: change custom high
8
: change custom buffer
9
: apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]3
1
: Default
2
: custom
Enter boundary level type => : (1..2) [1] 2
Index ThresholdName
216 eportRXPerf216
217 eportRXPerf217
218 eportRXPerf218
219 eportRXPerf219
220 eportRXPerf220
221 eportRXPerf221
222 eportRXPerf222
223 eportRXPerf223
Threshold boundary level is set at : Custom.
.
.
.
Figure 3-2
1
: change behavior type
2
: change behavior interval
3
: change threshold boundary level
4
: change custom unit
5
: change custom timebase
6
: change custom low
7
: change custom high
8
: change custom buffer
9
: apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]9.
.
.
Figure 3-3
Note
To ensure that your threshold setting configuration takes effect, remember to apply the threshold
boundary changes, and then change the threshold boundary level to Custom.
Fabric Watch Administrator's Guide
Publication Number: 53-1000243-01
shows how to change the threshold boundary level to custom so that the new custom value of
shows how to apply the custom value; unless you apply the value, it does not take effect.
BehaviorType
Triggered
Triggered
Triggered
Triggered
Triggered
Triggered
Triggered
Triggered
Changing the Threshold Boundary Level
Applying Threshold Boundary Changes
Configuring Fabric Watch Thresholds
11 : change threshold alarm level
12 : change changed alarm
13 : change belowalarm
14 : change abovealarm
15 : change inBetween alarm
16 : apply threshold alarm changes
17 : cancel threshold alarm changes
18 : return to previous page
BehaviorInt
1
1
1
1
1
1
1
1
11 : change threshold alarm level
12 : change changed alarm
13 : change belowalarm
14 : change abovealarm
15 : change inBetween alarm
16 : apply threshold alarm changes
17 : cancel threshold alarm changes
18 : return to previous page