Venting Requirements - Maytag MEDB800VB - Bravos Steam Electric Dryer Use And Care Manual

Steam fabric care system electric dryer
Table of Contents

Advertisement

Available languages

Available languages

Optional 3-wire connection
Use for direct wire or power supply cord where local codes do not permit connecting
cabinet-ground conductor to neutral wire.
1. Remove center silver-colored terminal block screw.
2. Remove neutral ground wire from external ground conductor screw. Connect neutral
ground wire and the neutral wire (white or center wire) of power supply cord/cable under
center, silver-colored terminal block screw. Tighten screw.
A
B
A. External ground conductor screw
B. Neutral ground wire
C. Center silver-colored terminal block screw
D. Neutral wire (white or center wire)
E.
3
/
" (19 mm) UL listed strain relief
4
F. Grounding path determined by a qualified electrician
3. Connect the other wires to outer terminal block screws. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-
down screw.
6. Connect a separate copper ground wire from the external ground conductor screw to an
adequate ground.
C
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
D
Failure to follow these instructions can result in death
or fire.
E
F
WARNING:
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, attic,
crawlspace, or a concealed space of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure exhaust hood is not plugged
with lint.
Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.
Review Vent system chart. Modify existing vent system if necessary to achieve the best
drying performance. Only rigid or flexible metal duct shall be used for exhausting.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (102 mm) heavy metal exhaust vent and clamps must be used.
Vent products can be purchased from your dealer or by calling Maytag Services. For more
information, see the "Assistance or Service" section.

Venting Requirements

WARNING
Fire Hazard
To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.
4"
102 mm
4" (102 mm) heavy metal exhaust vent
15