GE PSDF5RGXBB - 24.6 cu. Ft. Refrigerator Owner's Manual page 44

Models 22, 23, 25, 26, 27 and 29
Table of Contents

Advertisement

Available languages

Available languages

Performance Data Sheet
SmartWater Filtration S stem-GE
This s stem has been tested and certified in filter model GE MWF according to NSF/ANSI Standards 42 and 53 for reduction of the substances listed below. The
concentration of the indicated substances in water entering the s stem was reduced to a concentration less than or equal to the permissible limit for water
leaving the s stem, as specified in NSF/ANSI Standards 42 and 53.* (Safet factors built in for unmetered usage)
Standard No. 42: Aesthetic effects
Substance
Reduction
Average Influent
Chlorine Taste
2.0 mg/L
& Odor
Nominal Particulate
7,833,333 pts/mL At least 10,000 particles/mL 99.7%
Class I, ≥0.5 to <1.0 μm
Standard No. 53: Health effects
Substance
Reduction
Average Influent
Cyst*
147,5000 cysts/L Minimum 50,000 cysts/L
Asbestos
47 MF/L
Atrazine
0.009 mg/L
Benzene
0.016 mg/L
Carbofuran
0.08 mg/L
Endrin
0.006 mg/L
Lead @ pH 6.5
0.152 mg/L
Lead @ pH 8.5
0.148 mg/L
Lindane
0.002 mg/L
Mercury @ pH 6.5
0.0058 mg/L
Mercury @ pH 8.5
0.0061 mg/L
P-Dichlorobenzene
0.222 mg/L
Tetrachloroethylene
0.015 mg/L
Toxaphene
0.015 mg/L
2, 4-D
0.218 mg/L
*Based on the use of Cryptosporidium parvum oocysts
Capacity 300 gallons (1,135 liters). Contaminant reduction determined by NSF testing.
Application Guidelines/Water Supply Parameters
Service Flow
Water Supply
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Operating Specifications
• Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
• Temperature: 33–100°F (0.6–38°C)
• Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
trapped air.
expected to drop below 33°F (1°C). Do not install s stems in areas where
ambient temperatures ma go above 100ºF or below 40°F. Do not install
on a hot water suppl .
Special Notices
• Installation instructions are included with the product when shipped.
• This drinking water s stem must be maintained according to manufacturer's
instructions, including replacement of filter cartridges.
• Do not use with water that is microbiologicall unsafe or of unknown qualit
without adequate disinfection before or after the s stem. S stems certified for
c st reduction ma be used on disinfected water that ma contain filterable c sts.
Tested and Certified b NSF International against ANSI/NSF Standards 42 and 53 in model GE MWF for the reduction of:
Standard No. 42: Aesthetic Effects
• Chemical
– Chlorine Taste and Odor
GE
Appliances
Appliance Park
Louisville, KY 40225
geapplianceparts.com
44
NSF Specified Challenge
Concentration
2.0mg/L ± 10%
NSF Specified Challenge
Concentration
10
7
to 10
8
fibers/L; fibers
greater than 10 μm in length
0.009 mg/L ± 10%
0.015 mg/L ± 10%
0.08 mg/L ± 10%
0.006 mg/L ± 10%
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.002 mg/L ± 10%
0.006 mg/L ± 10%
0.006 mg/L ± 10%
0.225 mg/L ± 10%
0.015 mg/L ± 10%
0.015 mg/L ± 10%
0.210 mg/L ± 10%
0.5 gpm (1.9 lpm)
Potable Water
• Mechanical Filtration
– Particulate Reduction, Class I
®
MWF Cartridge
Average %
Average Product
Reduction
Water Concentration
97.5%
0.05 mg/L
18,617 pts/mL
Average %
Average Product
Reduction
Water Concentration
99.99%
1 cyst/L
>99%
<1 MF/L
94.5%
0.0005 mg/L
96.7%
0.0005 mg/L
98.7%
0.001 mg/L
95.6%
0.0003 mg/L
99.3%
0.001 mg/L
99.3%
0.001 mg/L
99%
0.00002 mg/L
93.2%
0.0004 mg/L
93.2%
0.0004 mg/L
99.7%
0.005 mg/L
96.6%
0.0005 mg/L
93.2%
0.001 mg/L
99.5%
0.0009 mg/L
Water Pressure
Water Temperature
• The contaminants or other substances removed or reduced b this water
treatment s stem are not necessaril in our water.
• Check for compliance with the applicable state and local laws and regulations.
• Note that while the testing was performed under standard laborator conditions,
actual performance ma var . S stems must be installed and operated in
accordance with manufacturer's recommended procedures and guidelines.
• Installation and use MUST compl with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. If our water pressure exceeds 80 psi
(552 kPa), ou should install a pressure-limiting valve. Contact a plumbing
professional if ou are uncertain how to check our water pressure.
• Do not install where water hammer conditions ma occur. If water hammer
conditions exist ou must install a water hammer arrester. Contact a plumbing
professional if ou are uncertain how to check for this condition.
controlling pressure due to thermal expansion must be installed.
Standard No. 53: Health Effects
• Chemical Reduction
– Atrazine Reduction
– Endrin Reduction
– Benzene and Carbofuran Reduction
– 1,4 Dichlorobenzene and
2,4-D Reduction
Max Permissible Product
NSF Reduction
Water Concentration
Requirements
N/A
≥50%
N/A
≥85%
Max Permissible Product
NSF Reduction
Water Concentration
Requirements
N/A
≥99.95%
N/A
≥99%
0.003 mg/L
N/A
0.005 mg/L
N/A
0.04 mg/L
N/A
0.002 mg/L
N/A
0.010 mg/L
N/A
0.010 mg/L
N/A
0.0002 mg/L
N/A
0.002 mg/L
N/A
0.002 mg/L
N/A
0.075 mg/L
N/A
0.005 mg/L
N/A
0.003 mg/L
N/A
0.07 mg/L
N/A
40–120 psi (2.8–8.2 bar)
33ºF–100ºF (0.6ºC–38ºC)
– Lead and Lindane Reduction
– Mercur and Toxaphene Reduction
• Mechanical Filtration
– C st and Asbestos Reduction
© 2010 GE Compan
NSF Test
Report
J-00077703
J-00077704
NSF Test
Report
J-00077721
J-00077707
J-00077708
J-00077717
J-00077718
J-00082185
J-00077722
J-00077723
J-00077726
J-00077727
J-00077728
J-00077729
J-00082184
J-00077730
J-00077705
REPLACEMENT
ELEMENT
PC61278B

Advertisement

Table of Contents
loading

Table of Contents