Biostar M7TDF Datasheet page 54

Engineering validation test report
Hide thumbs Also See for M7TDF:
Table of Contents

Advertisement

Blue cells need to be filled in with lab measurement
Yellow cells need to have the overall design tolerance entered
VID Voltage:
Tolerance:
+Tolerance
- Tolerance
Vdmm
Vscope
Vfb_nl
Static Voltage Measurements at pins AC14/AC15
Current
0
10
20
30
40
50
60
Ripple Voltage Measurements (mV) at pins AC14/AC15
Current
0
10
20
30
40
50
60
Load Step
0A to 0A
0A to 10A
0A to 20A
0A to 30A
0A to 40A
0A to 50A
0A to 60A
54
1.452
1.466
1.452
Measured Static Voltage
1.452
1.440
1.427
1.412
1.398
1.383
1.365
Measurement
17.600
18.800
19.000
23.000
27.200
28.200
30.200
Transient Min (mV) at pins AC14/AC15
Current
0
10
20
30
40
50
60
1.475 V
1.00% Overall
0.007 V
0.007 V
V
V
V
Units
V
V
V
V
V
V
V
Units
mV
mV
mV
mV
mV
mV
mV
Measurement
25.20
62.80
89.00
109.00
130.00
147.00
166.00
Units
mV
mV
mV
mV
mV
mV
mV