Whirlpool WED9400ST Use And Care Manual page 9

Duet electronic electric dryer
Table of Contents

Advertisement

Power Supply Cord
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals
(gold).
Securely tighten
all electrical
connections.
Failure to do so can result in death, fire, or
electrical shock.
Direct Wire
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain
relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal
(silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining
2 supply wires to remaining
2 terminals (gold).
Securely tighten
all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
1. Disconnect
power.
2. Remove the hold-down
screw and terminal block cover.
D
B
A. Neutral ground wire
B. External ground conductor screw
C. Center, silver-colored
terminal block screw
D. Terminal block cover and hold-down
screw
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a 3/4"(1.9 cm) UL listed strain
relief (UL marking on strain relief). Put the tabs of the two
clamp sections into the hole below the terminal block
opening so that one tab is pointing up and the other is
pointing down, and hold in place. Tighten strain relief
screws just enough to hold the two clamp sections
together.
i ........................... C
A. Strain relief tab pointing
up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing
down

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents