Whirlpool WED9400ST Use And Care Manual page 12

Duet electronic electric dryer
Table of Contents

Advertisement

3.
Connect ground wire (green or bare) of direct wire cable to
external ground conductor screw. Tighten screw.
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver-colored
terminal screw of the
terminal block. Tighten screw.
F
A. External ground conductor screw
B. Ground wire (green or bare) of power supply cable
C. 3/4"(1.9 cm) UL listed strain relief
D. Center silver-colored
terminal block screw
E. Neutral ground wire
F Neutral wire (white or center wire)
4.
Place the hooked ends of the other direct wire cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
!! !!
5. Tighten strain relief screw.
6. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
7. You have completed your electrical connection.
Now go to
"Venting Requirements."
3-wire connection:
Power supply cord
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
B
C
D
E
A. 3-wire receptacle (NEMA type lO-30R)
B. 3-wire plug
C. Neutral prong
D. Spade terminals with up turned ends
E. _" (1.9 cm) UL listed strain relief
F. Ring terminals
G. Neutral (white or center wire)
1. Loosen or remove center silver-colored
terminal block screw.
E
A. External ground conductor
screw
B. Neutral ground wire
C. Center silver-colored
terminal block screw
D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL Iisted strain relief
Connect the other wires to outer terminal block screws.
Tighten screws.
!! !!
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. You have completed your electrical connection.
Now go to
"Venting Requirements."
3-wire connection: Direct wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 31/2 '' (8.9 cm) of outer covering from end of cable. Strip
insulation back 1" (2.5 cm). If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
12