Drolet EVEREST DH04200 Owner's Manual

Drolet EVEREST DH04200 Owner's Manual

Drolet oil burning stove owner's manual

Advertisement

Quick Links

OWNER`S MANUAL
OIL BURNING STOVE
EVEREST
Vérified and tested following
CAN/CSA B140.3 et UL 896 standards by:
Intertek Testing Services
Manufactured by:
1700 Léon-Harmel
Québec, (Québec)
G1N 4R9
www.drolet.ca
tel : (418 ) 527-3060
Fax : (418 ) 527-4311
READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE
990615/45088A_feb 03

Advertisement

Table of Contents
loading

Summary of Contents for Drolet EVEREST DH04200

  • Page 1 Vérified and tested following CAN/CSA B140.3 et UL 896 standards by: Intertek Testing Services Manufactured by: 1700 Léon-Harmel Québec, (Québec) G1N 4R9 www.drolet.ca tel : (418 ) 527-3060 Fax : (418 ) 527-4311 READ THESE INSTRUCTIONS AND SAVE FOR REFERENCE 990615/45088A_feb 03...
  • Page 2: Table Of Contents

    TECHNICAL DATA ... 1 INSTALLATION INSTRUCTIONS ... 2 LOCATING THE STOVE ... 2 CHIMNEY INFORMATIONS... 3 CONNECTING THE STOVE TO THE CHIMNEY ... 4 LEVELING THE UNIT... 5 FIXATION OF STOVE TO FLOOR... 6 CONNECTING STOVE TO OIL TANK ... 6 AJUSTEMENT THE DRAUGHT...
  • Page 3: Installation Instructions

    Figure 1 : CORNER INSTALLATION Figure 3 : WALL INSTALLATION • IMPORTANT: It is essential to ensure that the room where the stove is located is sufficiently ventilated to provide an adequate air supply. • If your home is well insulated, it is possible that you will have to install an outside fresh air intake.
  • Page 4: Technical Data

    • Before the hook up of the stove, check if the chimney is in good condition and that the quality of the flue pipe will allow a sufficient draught. For a good combustion, refer to the technical data of the stove to know the minimum draught required.
  • Page 5: Connecting The Stove To The Chimney

    • The gases are vented from the back of the unit. The female part of the black pipe connector has to be installed toward the flue connector of the stove. Secure all connections with the (3) self taping screws, with 120 distance between each of them.
  • Page 6: Leveling The Unit

    • Now that the stove is in place and properly hooked up to the chimney, you have to adjust the level on the burner. • Put the level in the middle of the burner parallel to the door. (Figure 9A). Screw or unscrew the adjustable legs to level the burner with a 7/16"...
  • Page 7: Connecting Stove To Oil Tank

    • Use only copper piping to connect tank to stove. • Make sure that there is a small slope on the connection from the tank toward the stove. • A 3" (75 mm) down slope is needed on the tank itself, from the outlet towards the other end of the tank.
  • Page 8: Adjusting The Draught

    • Your stove operated with natural draught, created by the ascension of combustion gases in the chimney. This movement creates a siphon effect in the stove and forces ambient air to go in the burner by the holes in its surround. These orifices let air in for combustion.
  • Page 9: Operation Instructions

    OPERATION INSTRUCTIONS • Your stove has been designed to work with oil #1 or #2. DO NOT USE GASOLINE, CRANKCASE OIL OR ANY OIL CONTAINING GASOLINE. The manufacturer declines all responsibility regarding damage cause by using other combustibles. • Make sure to use oil without impurities which may plug filters and valve’s orifice. Impurities only give an improper combustion.
  • Page 10: Changing Intensity

    Note : Do not leave matches or other materials in the burner in order to keep it clean. It allows a better combustion. IF YOU MISS THE STOVE’S LIGHTING, ALWAYS WAIT FOR THE BURNER TO COOL DOWN TO ROOM TEMPERATURE BEFORE USING BURNING ALCOHOL AGAIN.
  • Page 11: Turning The Stove Off

    • Set the flow regulating handle to position ‘’0’’. • If you plan to keep the stove off for a long while, it is recommended to disarm the valve’s lever and close the tap on the pipe between the stove and your oil tank.
  • Page 12: Troubleshooting Guide

    PROBLEMS ON POSITION 6 (MAXIMUM) THE FLAME IS LONG AND SMOKY, THERE SUIT BUILD UPON THE GLASS. ON POSITION 1 (MINIMUM) THE FLAME PRODUCES SMOKE AND SUITS THE GLASS. ON POSITION 1 (MINIMUM) THE FLAME PRODUCES SMOKE AND SUITS THE GLASS.
  • Page 13 Air pocket is stocked in the oil line. Oil #2 is used in exterior tank. Partial or total obstruction by impurities in oil line or filters. The stove has been lit while excess of oil was in the burner. Page 12 of 15 SOLUTION 1. Tighten...
  • Page 14: Spare Parts

    After years of use, if you need to replace some parts, please contact your SUPPLIER or one of our Drolet approved DEALERS. • Give him product data as displayed in your warranty voucher or on your appliance’s name plate at the rear.
  • Page 15 SPARE PARTS (CONT’D) Figure 16: EVEREST EXPLODED VIEW, SPARE PARTS LIST Page 14 of 15...
  • Page 16 Gas units : Ceramic glass, valve, burner, piezo ignitor, pilot, blower and thermodisc. • Drolet Oil Stoves : Burner, valve rings, cleaning tee and electrical components. EXCLUSIONS This warranty will not cover labour costs or any costs related to damages caused by faulty installation, repairs, abusive use or wrong usage of the product, either by a contractor, a service representative or the buyer himself.

This manual is also suitable for:

Everest

Table of Contents