Download Print this page

Frigidaire FARG4044MW Specifications page 3

14 dry cycles 7.0 cu. ft. d.o.e. gas
Hide thumbs Also See for FARG4044MW:

Advertisement

Top Load Dryer Specifications
Product Shipping Weight (approx.) – 143 Lbs.
Designed for HOME USE only, not recommended for commercial
application.
An electrical supply with grounded three-prong receptacle is
required. The power supply circuit must be installed in accordance
with current edition of National Electrical Code (ANSI/NFPA 70)
and local codes & ordinances. (Do not use same circuit as washer.)
Voltage Rating – 120V / 60 Hz / 15 Amps
Amps @ 120 Volts = 9.0 Amps
Connected Load (kW Rating) @ 120 Volts = 1.0 kW
Equipped with 120V 3-wire power supply cord, approx. 60" long.
Always consult local and national electric & gas codes.
Dryer can be installed in recess or closet requiring 0" minimum
installation clearance around sides and back of unit. To achieve 0"
minimum rear clearance, dryer MUST be vented straight back. Closet
installation requires additional 1" minimum clearance between front of
unit and vented door. Door MUST be vented with 120 sq. in. minimum
louvered opening, equally divided, located 3" from top and bottom
of door. A louvered door with equivalent air openings for full-length
of door is acceptable. Air openings MUST remain unobstructed with
door installed. (For additional installation details, refer to Product
Installation Guide on web.)
Do NOT install in area exposed to dripping water or outdoor weather
conditions; where gasoline or other flammables are kept or stored; or
where dryer comes in contact with curtains, drapes or anything that
will obstruct flow of combustion and ventilation air.
USA
10200 David Taylor Drive
Charlotte, NC 28262
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
FARG4044M 06/12
1-800-FRIGIDAIRE
frigidaire.com
1-800-265-8352
frigidaire.ca
© 2012 Electrolux Home Products, Inc.
FARG4044M W
For garage installation, dryer MUST be located minimum 18" above floor.
Floor MUST be solid with 1" maximum slope. Do NOT install on
carpeted surface.
Dryer MUST exhaust to outside of building, NOT into any concealed
space.
Exhaust installation requires minimum 4"-diameter rigid or semi-rigid
metal duct with approved, unobstructed vent hood having swing-out
damper(s). If installing rigid metal duct (preferred), do not exceed
MAXIMUM venting run length of 64 ft., allow deductions for elbows
and vents. If installing semi-rigid metal duct, do not exceed MAXIMUM
venting run length of 8 ft., always allow deductions for elbows and
vents (Refer to Product Installation Guide on web for additional
information). Do NOT use flexible plastic or metal foil duct and use
shortest run possible.
Gas supply line should be 1/2" pipe and MUST have individual
shutoff valve.
Leveling legs supplied to level dryer properly and reduce excessive
noise and vibration.
For manufactured or mobile home installation optional Mobile Home
Installation Kit (PN # 137067200) required. (For specific installation
details, refer to Product Installation Guide on web.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
Mobile Home Installation Kit – (PN # 137067200).
LP Gas Conversion Kit – (PN # PCK4200).
Drying Rack – (PN # 137067300).
Dryer
7.0 Cu. Ft. D.O.E. Gas
Specifications
subject to change.

Advertisement

loading

This manual is also suitable for:

Farg4044m w