GET TO KNOW YOUR WATER HEATER - GAS MODELS
A Vent Pipe–Exhaust
B Vent Terminal
C Vent Adapter-Rubber Boot
D Blower Assembly
E Cold Water Inlet
F Inlet Water Shut-off Valve
G Union
H Inlet Dip Tube
J Anode**
K Hot Water Outlet
L Outlet Receptacle (115 VAC)
M Temperature-Pressure Relief Valve
GAS MODELS
WITH HOT SURFACE IGNITION
& 2", 3" OR 4" PVC VENT CAPABILITY

TYPICAL INSTALLATION

N Flue
O Flue Baffl e Assembly**
P Insulation
Q Control Harness
R Rating Plate
S
Gas Supply
T
Manual Gas Shut-off Valve
U
Ground Joint Union
V
Drip Leg (Sediment Trap)
W
Drain Valve
X
Gas Control Valve
Y Drain Pan
* ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS.
** LOCATED UNDER THE BLOWER ASSEMBLY.
*CAUTION: 115 VAC IN CONTROL HARNESS
AND INSIDE OUTER DOOR
B B
CC
D D
E E
F F
NATURAL HOT SURFACE IGNITER & MAIN BURNER
HOT
SURFACE
IGNITOR
PROPANE HOT SURFACE IGNITER & MAIN BURNER
HOT
SURFACE
IGNITOR
GAS CONTROL VALVE-THERMOSTAT
TEMPERATURE INDICATORS
TEMPERATURE ADJUSTMENT BUTTONS
FIGURE 1.
6
Z
Air Intake Screen - Base Pan
A A
Inner Door
Outer Door
HSI Burner Assembly
Air Intake Screen -
Blower Assembly
FV Sensor/Bracket Assembly
(40K & 50K Models Only)
FV Sensor/Bracket Assembly
(55K & 62.5K Models Only)
SENSOR
SENSOR

Hide quick links: