DESCRIPTION OF OPERATING
MODES
AUTO MODE
When operating in the AUTO mode, the AUTO mode
indicator lamp (A) will illuminate.
The control system will automatically select between AC
and GAS operation with AC having priority over GAS.
Either the AC indicator lamp (B) or the GAS indicator
lamp (C) will illuminate depending on the energy source
selected by the control system. If the control system is
operating with AC energy and it then becomes unavailable,
the system will automatically switch to GAS. As soon as
AC becomes available again the control will switch back
to AC regardless of the status of GAS operation.
GAS MODE
When operating in the GAS mode, the AUTO mode in-
dicator lamp (A) will be off and the GAS mode indicator
lamp (C) will be illuminated. This mode provides LP gas
operation only. The control system will activate the igni-
tion system and will make three attempt to light the burner
for a period of approximately 45 seconds with two min-
utes interval. If unsuccessful, the CHECK indicator lamp
(D) will illuminate and the GAS mode indicator lamp (C)
will turn off.
To restart GAS operation, press the main power ON/OFF
button (1) to the OFF and then ON position. The control
system will attempt a new ignition sequence.
If the refrigerator has not been used for a long time or
the LP tanks have just been refilled, air may be trapped
in the supply lines. To purge the air from the lines may
require resetting the main power ON/OFF button (1) three
or four times. If repeated attempts fail to start the LP gas
operation, check to make sure that the LP gas supply
tanks are not empty and all manual shutoff valves in the
lines are open. If the problem is still not corrected, con-
tact a service center for assistance.
If the control is switched to AC operation while the CHECK
indicator lamp is on, it will function properly, but the
CHECK indicator lamp will not go off until the main power
ON/OFF button is pressed to the OFF then ON position.
10
DISPLAY PANEL
A
ON
AUTO
1
2
OFF
AC
GAS
B
C
D
COLD
1
2
CHECK
LIMP MODE OF OPERATION
This control system contains a feature where it will con-
tinue to operate the cooling system in the event of a fail-
ure of a major operating component. Two different modes
of operation can occur in this category.
If for some reason the display module becomes non func-
tional, the control system will revert to full automatic op-
eration selecting the best energy source available with
AC, GAS priority. The temperature of the refrigerator will
be maintained at the MID position within normal tem-
perature tolerances. The power module will continually
attempt to reestablish operation of the display module.
The second limp mode of operation will execute when a
failure of the temperature sensing device or associated
electronic circuitry occurs. If this should occur, the con-
trol system will operate on the energy source selected
via the control panel. The cooling unit will run continu-
ously on the selected energy source. The refrigerator
will continue to operate in this mode indefinitely or until a
new sensor is installed and the system is reset.