Figure 1: Installing the Receiver Board in the Control's Cabinet
4. Setting the DIP switches (All Receivers):
a. Set the receiver's DIP switch (#2 through #4) to identify the
receiver's address (refer to the DIP switch chart in the
Summary of Connections Diagram on back cover).
b. Verify that DIP switch #1 is in the OFF position.
c. Set DIP switch #5 according to the following chart.
DIP SWITCH #5
For . . .
Commercial Fire Applications
Non-commercial Fire Applications
NOTES:
• If multiple receivers are used on one control, DIP switch #5
must be set to the same position on all receivers.
• DIP switch #5 reduces sensitivity during supervision
message reception. For commercial fire applications, DIP
switch #5 must be in the ON position.
5. Insert the wiring plug (with 4 flying leads) into the mating socket
on the receiver (see Summary of Connections Diagram on back
cover for socket location). Connect the 4 wires to the control's
corresponding keypad terminals (see "Interface Wiring" in the
SPECIFICATIONS section).
6. Install the antennas in the right-hand terminals of the two
terminal blocks at the upper edge of the circuit board, one into
each block's right-hand terminal, and tighten the screws to
secure them.
Caution: Avoid mounting the receiver antennas against a metal
surface.
7. Replace the unit's front cover using the supplied screw to secure
it.
8. Proceed with any programming of the control that may be
necessary for RF operation, and the installation of the system's
wireless transmitters, as described in the control's installation
and setup guide and the transmitter's installation instructions.
NOTES:
• The receiver can support up to 16 high security (encrypted)
wireless transmitters (keys). The total quantity of wireless
keys (encrypted and unencrypted) that can be used is
determined by the control panel.
• Wireless key buttons must be enrolled to zones in the control
panel via zone programming first. If the wireless key is to be
used for arming and disarming the VISTA-40 and up, a user
number must then be assigned to the wireless key via user
programming. If it is not done in this order, you will be unable
to respond successfully to the RF button zone number prompt
in user programming.
• If more than one receiver is being used and you are using
encrypted wireless keys, we recommend that you (a) enter the
GO/NO GO mode, (b) disconnect one receiver, (c) enroll all
encrypted keys into the connected receiver, (d) reconnect the
disconnected receiver, (e) exit the GO/NO GO mode, and then
HOLES FOR ANTENNAS
AND GROUNDING LUGS
CABINET
CIRCUIT BOARD
RECEIVER CIRCUIT BOARD
(See Detail D)
+
+
SUPPORTING SLOTS
CONTROL
CIRCUIT
BOARD
SCREW
OF MOUNTING
(2)
ANTENNA
(2)
GROUNDING
LUG
(2)
RCVR BRD
OF MOUNTING
+
ANTENNA
MOUNT
(2 PLACES)
DETAIL D
Set to . . .
ON
OFF
DETAIL A
SIDE VIEW
OF BOARD
DETAIL B
SIDE VIEW
CLIP
DETAIL C
SIDE VIEW
CLIP
pcb_RF_mount-V0
Figure 3: 5881ENHC UL Commercial Fire Installation
(f) repeat (a) through (e) for the receiver that was
disconnected.
• The RED LED located on the receiver's circuit board should be
used as an indicator of strong local radio frequency
interference. If this LED is continuously illuminated, the
receiver should be relocated.
After a successful enrollment of an encrypted key, the
GREEN LED blinks the number of spaces that are free for
additional encrypted key enrollment.
9. Replace the receiver's cover.
UL Commercial Fire Installation
For UL864 Commercial Fire Installations, you will need to purchase
separately the "5800BOX" (in which the circuit board will be
installed). Follow the instructions below and refer to Figure 3.
1. Mount the rear half of the 5800BOX directly to the wall in the
selected location, hinged side up. Secure using the 4 screws
provided and insert screw in tamper tab, refer to Installation, step
3c and Fig. 2.
2. Thread the ECP wire through the conduit and feed through the
opening at the side of the box rear.
3. Remove the circuit board from the 5881EN case and discard case.
Install the circuit board into the 5800BOX and secure using the 4
screws provided. Install each antenna, refer to Installation: Step 6.
4. Connect the ECP terminals as shown.
5. Insert slots on top of box cover into hinges on top of box back and
secure using 2 cover securing screws.
CONTROL
PANEL*
KEYPAD
TERMINALS
ON
CONTROL
BOARD
*CONTROL MUST BE CAPABLE OF
SUPPORTING A 5800 RF SYSTEM
Figure 4:
NOTE: For UL-864 Fire installations, ECP Isolator (PN ECP-ISO) is
required.
2
SCREW
5881ENHC-001-V0
Figure 2: Tamper Protection
MOUNTING
HOLES
4 (TYP)
MACHINE
SCREWS
4 (TYP)
COVER
SECURING
SCREWS
TO BURGLARY DEVICES
ECP
ISOLATOR
TO FIRE DEVICES
5881ENHC
TRANSCEIVER
Mounting UL Commercial Fire Applications
FRONT TAMPER
(REAR TAMPER)
ECP
CONNECTION
PLASTIC
CONDUIT
5883HC-001-V0
5800 SERIES
WIRELESS
TRANSMITTERS
2-WAY
TRANSMISSION
2-WAY
WIRELESS KEYPAD
(e.g. 5804BD)
OR
5800RL 2-WAY
RELAY MODULE
5883HC-002-V0

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Ademco 5881en seriesAdemco 5881enlAdemco 5881enmAdemco 5881enhAdemco 5881enhc